Spectrophotometric and HPLC determination of fleroxacin in tablets
Authorized Users Only
2001
Authors
Milovanović, Lj.Kapetanović, Vera
Popović, Gordana
Dugumović, Z.
Miljević, D.
Aleksić, Mara
Article (Published version)
Metadata
Show full item recordAbstract
Abstract
The paper describes and compares spectrophotometric and HPLC determination of fleroxacin in commercial tablets. The optimum conditions for spectrophotometric assay were found to be at pH < 3.5 (0.1 M HCl) at a wave length of 286 nm. HPLC analysis was carried out on a Beckman ODS 5 microns column in a pH 3 phosphoric acid solution (detector wave length 254 nm).
Source:
Pharmazie, 2001, 56, 2, 150-151Publisher:
- Govi-Verlag Pharmazeutischer Verlag Gmbh, Eschborn
DOI: 10.24355/dbbs.084-201812041524-2
ISSN: 0031-7144
PubMed: 11234343
WoS: 000166908400007
Scopus: 2-s2.0-0035112699
Collections
Institution/Community
PharmacyTY - JOUR AU - Milovanović, Lj. AU - Kapetanović, Vera AU - Popović, Gordana AU - Dugumović, Z. AU - Miljević, D. AU - Aleksić, Mara PY - 2001 UR - https://farfar.pharmacy.bg.ac.rs/handle/123456789/5496 AB - Abstract The paper describes and compares spectrophotometric and HPLC determination of fleroxacin in commercial tablets. The optimum conditions for spectrophotometric assay were found to be at pH < 3.5 (0.1 M HCl) at a wave length of 286 nm. HPLC analysis was carried out on a Beckman ODS 5 microns column in a pH 3 phosphoric acid solution (detector wave length 254 nm). PB - Govi-Verlag Pharmazeutischer Verlag Gmbh, Eschborn T2 - Pharmazie T1 - Spectrophotometric and HPLC determination of fleroxacin in tablets VL - 56 IS - 2 SP - 150 EP - 151 DO - 10.24355/dbbs.084-201812041524-2 ER -
@article{ author = "Milovanović, Lj. and Kapetanović, Vera and Popović, Gordana and Dugumović, Z. and Miljević, D. and Aleksić, Mara", year = "2001", abstract = "Abstract The paper describes and compares spectrophotometric and HPLC determination of fleroxacin in commercial tablets. The optimum conditions for spectrophotometric assay were found to be at pH < 3.5 (0.1 M HCl) at a wave length of 286 nm. HPLC analysis was carried out on a Beckman ODS 5 microns column in a pH 3 phosphoric acid solution (detector wave length 254 nm).", publisher = "Govi-Verlag Pharmazeutischer Verlag Gmbh, Eschborn", journal = "Pharmazie", title = "Spectrophotometric and HPLC determination of fleroxacin in tablets", volume = "56", number = "2", pages = "150-151", doi = "10.24355/dbbs.084-201812041524-2" }
Milovanović, Lj., Kapetanović, V., Popović, G., Dugumović, Z., Miljević, D.,& Aleksić, M.. (2001). Spectrophotometric and HPLC determination of fleroxacin in tablets. in Pharmazie Govi-Verlag Pharmazeutischer Verlag Gmbh, Eschborn., 56(2), 150-151. https://doi.org/10.24355/dbbs.084-201812041524-2
Milovanović L, Kapetanović V, Popović G, Dugumović Z, Miljević D, Aleksić M. Spectrophotometric and HPLC determination of fleroxacin in tablets. in Pharmazie. 2001;56(2):150-151. doi:10.24355/dbbs.084-201812041524-2 .
Milovanović, Lj., Kapetanović, Vera, Popović, Gordana, Dugumović, Z., Miljević, D., Aleksić, Mara, "Spectrophotometric and HPLC determination of fleroxacin in tablets" in Pharmazie, 56, no. 2 (2001):150-151, https://doi.org/10.24355/dbbs.084-201812041524-2 . .