Quantitative analysis of analgoantipyretics in dosage form using planar chromatography
Abstract
In the therapy of pain of weaker genesis, frequently used drugs usually represent a mix of analgoantipyretics of different chemical structures, mostly derivatives of salicylic acid, pyrazolone and p-aminophenol as well as derivatives of propionic and acetylsalicylic acid. For the determination of these drugs, different chromatographic methods have been applied, mostly HPLC, due to the the lower polarity (pyrazolones derivatives) and thermolability, as well as nonvolatility of compounds investigated. TLC method, considering advantages which include simplicity, reasonable sensitivity, rapidity, excellent resolving power and low cost has been successfully explored for the determination of analgoantipyretic compounds, The aim of this work was to develop a simple and rapid HPTLC method for the determination of acetylsalicylic acid, paracetamol, caffeine and phenobarbitone in dosage form. The determination of analgoantipyretics were performed on pre-coated HPTLC silica gel plates (10 x 20 cm...(2)) by development in the mobile phase dichlormethanethyl acetate-cyclohexane-isopropanol-0.1 M HCL formic acid (9:8:3:1.5:0.2:0.2 v/v/v/v/v/v). Migration distances (68.5 + 0.2 mm, 54.1 + 0.1 mm, 36.4 + 0.14 mtn and 85.9 + 0.11 mm for acetylsalicylic acid, paracetamol. caffeine and phenobarbitone, respectively) with low RSD values (0.13-0.39%) showed a satisfactory reproductivity of the chromatographic system. TLC scanner. was used for direct evaluation of the chromatograms in the reflectance/absorbance mode. Established calibration curves (r > 0.999), precision (0.3-1.02%) and detection limits, as well as recovery values (96.51 98.1%) were validated and found to be satisfactory. The method was found to be reproducible and convenient for the quantitative analysis of compounds investigated in their dosage forms.
Source:
Journal of Pharmaceutical and Biomedical Analysis, 2001, 24, 5-6, 1169-1173Publisher:
- Pergamon-Elsevier Science Ltd, Oxford
DOI: 10.1016/S0731-7085(00)00579-3
ISSN: 0731-7085
PubMed: 11248516
WoS: 000167764200051
Scopus: 2-s2.0-0035095348
Collections
Institution/Community
PharmacyTY - JOUR AU - Franeta, JT AU - Agbaba, Danica AU - Erić, Slavica AU - Pavkov, SP AU - Vladimirov, SD AU - Aleksić, Mirjana PY - 2001 UR - https://farfar.pharmacy.bg.ac.rs/handle/123456789/292 AB - In the therapy of pain of weaker genesis, frequently used drugs usually represent a mix of analgoantipyretics of different chemical structures, mostly derivatives of salicylic acid, pyrazolone and p-aminophenol as well as derivatives of propionic and acetylsalicylic acid. For the determination of these drugs, different chromatographic methods have been applied, mostly HPLC, due to the the lower polarity (pyrazolones derivatives) and thermolability, as well as nonvolatility of compounds investigated. TLC method, considering advantages which include simplicity, reasonable sensitivity, rapidity, excellent resolving power and low cost has been successfully explored for the determination of analgoantipyretic compounds, The aim of this work was to develop a simple and rapid HPTLC method for the determination of acetylsalicylic acid, paracetamol, caffeine and phenobarbitone in dosage form. The determination of analgoantipyretics were performed on pre-coated HPTLC silica gel plates (10 x 20 cm(2)) by development in the mobile phase dichlormethanethyl acetate-cyclohexane-isopropanol-0.1 M HCL formic acid (9:8:3:1.5:0.2:0.2 v/v/v/v/v/v). Migration distances (68.5 + 0.2 mm, 54.1 + 0.1 mm, 36.4 + 0.14 mtn and 85.9 + 0.11 mm for acetylsalicylic acid, paracetamol. caffeine and phenobarbitone, respectively) with low RSD values (0.13-0.39%) showed a satisfactory reproductivity of the chromatographic system. TLC scanner. was used for direct evaluation of the chromatograms in the reflectance/absorbance mode. Established calibration curves (r > 0.999), precision (0.3-1.02%) and detection limits, as well as recovery values (96.51 98.1%) were validated and found to be satisfactory. The method was found to be reproducible and convenient for the quantitative analysis of compounds investigated in their dosage forms. PB - Pergamon-Elsevier Science Ltd, Oxford T2 - Journal of Pharmaceutical and Biomedical Analysis T1 - Quantitative analysis of analgoantipyretics in dosage form using planar chromatography VL - 24 IS - 5-6 SP - 1169 EP - 1173 DO - 10.1016/S0731-7085(00)00579-3 ER -
@article{ author = "Franeta, JT and Agbaba, Danica and Erić, Slavica and Pavkov, SP and Vladimirov, SD and Aleksić, Mirjana", year = "2001", abstract = "In the therapy of pain of weaker genesis, frequently used drugs usually represent a mix of analgoantipyretics of different chemical structures, mostly derivatives of salicylic acid, pyrazolone and p-aminophenol as well as derivatives of propionic and acetylsalicylic acid. For the determination of these drugs, different chromatographic methods have been applied, mostly HPLC, due to the the lower polarity (pyrazolones derivatives) and thermolability, as well as nonvolatility of compounds investigated. TLC method, considering advantages which include simplicity, reasonable sensitivity, rapidity, excellent resolving power and low cost has been successfully explored for the determination of analgoantipyretic compounds, The aim of this work was to develop a simple and rapid HPTLC method for the determination of acetylsalicylic acid, paracetamol, caffeine and phenobarbitone in dosage form. The determination of analgoantipyretics were performed on pre-coated HPTLC silica gel plates (10 x 20 cm(2)) by development in the mobile phase dichlormethanethyl acetate-cyclohexane-isopropanol-0.1 M HCL formic acid (9:8:3:1.5:0.2:0.2 v/v/v/v/v/v). Migration distances (68.5 + 0.2 mm, 54.1 + 0.1 mm, 36.4 + 0.14 mtn and 85.9 + 0.11 mm for acetylsalicylic acid, paracetamol. caffeine and phenobarbitone, respectively) with low RSD values (0.13-0.39%) showed a satisfactory reproductivity of the chromatographic system. TLC scanner. was used for direct evaluation of the chromatograms in the reflectance/absorbance mode. Established calibration curves (r > 0.999), precision (0.3-1.02%) and detection limits, as well as recovery values (96.51 98.1%) were validated and found to be satisfactory. The method was found to be reproducible and convenient for the quantitative analysis of compounds investigated in their dosage forms.", publisher = "Pergamon-Elsevier Science Ltd, Oxford", journal = "Journal of Pharmaceutical and Biomedical Analysis", title = "Quantitative analysis of analgoantipyretics in dosage form using planar chromatography", volume = "24", number = "5-6", pages = "1169-1173", doi = "10.1016/S0731-7085(00)00579-3" }
Franeta, J., Agbaba, D., Erić, S., Pavkov, S., Vladimirov, S.,& Aleksić, M.. (2001). Quantitative analysis of analgoantipyretics in dosage form using planar chromatography. in Journal of Pharmaceutical and Biomedical Analysis Pergamon-Elsevier Science Ltd, Oxford., 24(5-6), 1169-1173. https://doi.org/10.1016/S0731-7085(00)00579-3
Franeta J, Agbaba D, Erić S, Pavkov S, Vladimirov S, Aleksić M. Quantitative analysis of analgoantipyretics in dosage form using planar chromatography. in Journal of Pharmaceutical and Biomedical Analysis. 2001;24(5-6):1169-1173. doi:10.1016/S0731-7085(00)00579-3 .
Franeta, JT, Agbaba, Danica, Erić, Slavica, Pavkov, SP, Vladimirov, SD, Aleksić, Mirjana, "Quantitative analysis of analgoantipyretics in dosage form using planar chromatography" in Journal of Pharmaceutical and Biomedical Analysis, 24, no. 5-6 (2001):1169-1173, https://doi.org/10.1016/S0731-7085(00)00579-3 . .