High-performance liquid chromatographic method for the assay of dexamethasone and xylometazoline in nasal drops containing methyl p-hydroxybenzoate
Abstract
A rapid and sensitive high-performance liquid chromatographic method has been developed for the determination of dexamethasone sodium phosphate (DSP), xylometazoline hydrochloride (XMC) and methyl p-hydroxybenzoate (MHB). An assay of the compounds has been performed on a HPLC system GBC 1210, at controlled room temperature, on a Nucleosil C-8 column (250x3 mm, 5 mum). The mobile phase was acetonitrile-water (35:65, v/v), at a flow-rate of 1 ml min(-1). The parameters for validation such as linearity (r>0.9996), precision (RSD: 0.51-(1.93%), limit of detection and quantification (2.032(.)10(-4) and 4.063(.)10(-4) mg ml(-1) for DSP, 9.7(.)10(-5) and 1.953(.)10(-4) mg ml(-1) for XMC, 1.953(.)10(-4) and 3.096(.)10(-4) mg ml(-1) for MHB) have also been reported. The method was applied to the determination of DSP, XMC and MHB in nasal drops. The statistical parameters were found to be satisfactory, with recovery values ranging froth 98.69 to 101.60% (RSD: 0.32-1.03%). The method is simple an...d accurate and therefore suitable for the simultaneous determination of these compounds in dosage form.
Source:
Journal of Chromatography A, 2002, 949, 1-2, 79-82Publisher:
- Elsevier Science BV, Amsterdam
DOI: 10.1016/S0021-9673(01)01510-2
ISSN: 0021-9673
PubMed: 11999760
WoS: 000174633300010
Scopus: 2-s2.0-0037040560
Collections
Institution/Community
PharmacyTY - JOUR AU - Milojević, Z AU - Agbaba, Danica AU - Erić, Slavica AU - Boberić-Borojević, D AU - Ristić, P AU - Solujić, M PY - 2002 UR - https://farfar.pharmacy.bg.ac.rs/handle/123456789/325 AB - A rapid and sensitive high-performance liquid chromatographic method has been developed for the determination of dexamethasone sodium phosphate (DSP), xylometazoline hydrochloride (XMC) and methyl p-hydroxybenzoate (MHB). An assay of the compounds has been performed on a HPLC system GBC 1210, at controlled room temperature, on a Nucleosil C-8 column (250x3 mm, 5 mum). The mobile phase was acetonitrile-water (35:65, v/v), at a flow-rate of 1 ml min(-1). The parameters for validation such as linearity (r>0.9996), precision (RSD: 0.51-(1.93%), limit of detection and quantification (2.032(.)10(-4) and 4.063(.)10(-4) mg ml(-1) for DSP, 9.7(.)10(-5) and 1.953(.)10(-4) mg ml(-1) for XMC, 1.953(.)10(-4) and 3.096(.)10(-4) mg ml(-1) for MHB) have also been reported. The method was applied to the determination of DSP, XMC and MHB in nasal drops. The statistical parameters were found to be satisfactory, with recovery values ranging froth 98.69 to 101.60% (RSD: 0.32-1.03%). The method is simple and accurate and therefore suitable for the simultaneous determination of these compounds in dosage form. PB - Elsevier Science BV, Amsterdam T2 - Journal of Chromatography A T1 - High-performance liquid chromatographic method for the assay of dexamethasone and xylometazoline in nasal drops containing methyl p-hydroxybenzoate VL - 949 IS - 1-2 SP - 79 EP - 82 DO - 10.1016/S0021-9673(01)01510-2 ER -
@article{ author = "Milojević, Z and Agbaba, Danica and Erić, Slavica and Boberić-Borojević, D and Ristić, P and Solujić, M", year = "2002", abstract = "A rapid and sensitive high-performance liquid chromatographic method has been developed for the determination of dexamethasone sodium phosphate (DSP), xylometazoline hydrochloride (XMC) and methyl p-hydroxybenzoate (MHB). An assay of the compounds has been performed on a HPLC system GBC 1210, at controlled room temperature, on a Nucleosil C-8 column (250x3 mm, 5 mum). The mobile phase was acetonitrile-water (35:65, v/v), at a flow-rate of 1 ml min(-1). The parameters for validation such as linearity (r>0.9996), precision (RSD: 0.51-(1.93%), limit of detection and quantification (2.032(.)10(-4) and 4.063(.)10(-4) mg ml(-1) for DSP, 9.7(.)10(-5) and 1.953(.)10(-4) mg ml(-1) for XMC, 1.953(.)10(-4) and 3.096(.)10(-4) mg ml(-1) for MHB) have also been reported. The method was applied to the determination of DSP, XMC and MHB in nasal drops. The statistical parameters were found to be satisfactory, with recovery values ranging froth 98.69 to 101.60% (RSD: 0.32-1.03%). The method is simple and accurate and therefore suitable for the simultaneous determination of these compounds in dosage form.", publisher = "Elsevier Science BV, Amsterdam", journal = "Journal of Chromatography A", title = "High-performance liquid chromatographic method for the assay of dexamethasone and xylometazoline in nasal drops containing methyl p-hydroxybenzoate", volume = "949", number = "1-2", pages = "79-82", doi = "10.1016/S0021-9673(01)01510-2" }
Milojević, Z., Agbaba, D., Erić, S., Boberić-Borojević, D., Ristić, P.,& Solujić, M.. (2002). High-performance liquid chromatographic method for the assay of dexamethasone and xylometazoline in nasal drops containing methyl p-hydroxybenzoate. in Journal of Chromatography A Elsevier Science BV, Amsterdam., 949(1-2), 79-82. https://doi.org/10.1016/S0021-9673(01)01510-2
Milojević Z, Agbaba D, Erić S, Boberić-Borojević D, Ristić P, Solujić M. High-performance liquid chromatographic method for the assay of dexamethasone and xylometazoline in nasal drops containing methyl p-hydroxybenzoate. in Journal of Chromatography A. 2002;949(1-2):79-82. doi:10.1016/S0021-9673(01)01510-2 .
Milojević, Z, Agbaba, Danica, Erić, Slavica, Boberić-Borojević, D, Ristić, P, Solujić, M, "High-performance liquid chromatographic method for the assay of dexamethasone and xylometazoline in nasal drops containing methyl p-hydroxybenzoate" in Journal of Chromatography A, 949, no. 1-2 (2002):79-82, https://doi.org/10.1016/S0021-9673(01)01510-2 . .