Stojanović, Jelena

Link to this page

Authority KeyName Variants
4089ade9-69c9-4a0a-9d89-0f4160ba618b
  • Stojanović, Jelena (1)
Projects
No records found.

Author's Bibliography

Monitoring of the photochemical stability of carvedilol and its degradation products by the RP-HPLC method

Stojanović, Jelena; Vladimirov, Sote; Marinković, Valentina; Veličković, Dragan; Sibinović, Predrag

(Srpsko hemijsko društvo, Beograd, 2007)

TY  - JOUR
AU  - Stojanović, Jelena
AU  - Vladimirov, Sote
AU  - Marinković, Valentina
AU  - Veličković, Dragan
AU  - Sibinović, Predrag
PY  - 2007
UR  - https://farfar.pharmacy.bg.ac.rs/handle/123456789/999
AB  - A sensitive, selective, precise and stability-indicating, new high-performance liquid chromatographic method for the analysis of carvedilol both as a bulk drug and in formulations was developed and validated. As the method could effectively separate the drug from its degradation products, it can be employed as a stability-indicating one. The method was validated for linearity, selectivity, precision, robustness, LOD, LOQ and accuracy. The chromatographic separation was achieved on a Chromolit RP8e, 100x4.6 mm, analytical column. The mobile phase consisted of a mixture of acetonitrile and water (45:55, V/V) (pH 2.5), pH adjusted with formic acid. The absorbance was monitored with a UV detector at 280 nm and the temperature of the analyses was 40°C. The flow rate was 0.5 mL/min. The linearity (r≥ 0.999), reproducibility (0.68-1.27 %) and recovery (99.71-101.58) were found to be satisfactory. This method enables the simultaneous determination of carvedilol and its degradation products, as well as stability.
AB  - Karvedilol je neselektivni beta blokator sa vazodilatatornim i antioksidativnim svojstvima. Primenjuje se u terapiji hipertenzije, angine pektoris i kongestivne srčane insuficijencije. Razvijena je i validirana nova HPLC metoda za istovremenu kvalitativnu i kvantitativnu analizu karvedilola i njegovih nečistoća kao i za praćenje fotohemijske stabilnosti ovog jedinjenja. Metoda je validirana na linearnost, selektivnost, preciznost, robustnost, LOD, LOQ i tačnost. Optimalni uslovi postignuti su korišćenjem hromatografske kolone Chromolit RP 8e, 100x4,6 mm. Mobilnu fazu predstavlja smeša acetonitrila i vode u odnosu 45:55 pri pH 2,5. Analiza se odvija na temperaturi od 40°C pri protoku 0,5 ml/min a talasna dužina UV detektora iznosi 280 nm. Linearnost (r≥0,999), reproduktivnost (0,68-1,27%), i rikaveri (99,71-101,58) pokazuju zadovoljavajuće vrednosti. Hromatografska analiza je pokazala da se kao glavni proizvod degradacije karvedilola javlja 4-hidroksikarbazol, dok nečistoća C nije prisutna pod ovim uslovima. Predložena RP-HPLC metoda je brza, precizna, tačna, osetljiva, pouzdana i primenljiva za kvalitativnu i kvantitativnu analizu KarvileksR tablete, kao i za praćenje stabilnosti ovog leka.
PB  - Srpsko hemijsko društvo, Beograd
T2  - Journal of the Serbian Chemical Society
T1  - Monitoring of the photochemical stability of carvedilol and its degradation products by the RP-HPLC method
T1  - Praćenje fotohemijske stabilnosti karvedilola i njegovih degradacionih proizvoda RP-HPLC metodom
VL  - 72
IS  - 1
SP  - 37
EP  - 44
DO  - 10.2298/JSC0701037S
ER  - 
@article{
author = "Stojanović, Jelena and Vladimirov, Sote and Marinković, Valentina and Veličković, Dragan and Sibinović, Predrag",
year = "2007",
abstract = "A sensitive, selective, precise and stability-indicating, new high-performance liquid chromatographic method for the analysis of carvedilol both as a bulk drug and in formulations was developed and validated. As the method could effectively separate the drug from its degradation products, it can be employed as a stability-indicating one. The method was validated for linearity, selectivity, precision, robustness, LOD, LOQ and accuracy. The chromatographic separation was achieved on a Chromolit RP8e, 100x4.6 mm, analytical column. The mobile phase consisted of a mixture of acetonitrile and water (45:55, V/V) (pH 2.5), pH adjusted with formic acid. The absorbance was monitored with a UV detector at 280 nm and the temperature of the analyses was 40°C. The flow rate was 0.5 mL/min. The linearity (r≥ 0.999), reproducibility (0.68-1.27 %) and recovery (99.71-101.58) were found to be satisfactory. This method enables the simultaneous determination of carvedilol and its degradation products, as well as stability., Karvedilol je neselektivni beta blokator sa vazodilatatornim i antioksidativnim svojstvima. Primenjuje se u terapiji hipertenzije, angine pektoris i kongestivne srčane insuficijencije. Razvijena je i validirana nova HPLC metoda za istovremenu kvalitativnu i kvantitativnu analizu karvedilola i njegovih nečistoća kao i za praćenje fotohemijske stabilnosti ovog jedinjenja. Metoda je validirana na linearnost, selektivnost, preciznost, robustnost, LOD, LOQ i tačnost. Optimalni uslovi postignuti su korišćenjem hromatografske kolone Chromolit RP 8e, 100x4,6 mm. Mobilnu fazu predstavlja smeša acetonitrila i vode u odnosu 45:55 pri pH 2,5. Analiza se odvija na temperaturi od 40°C pri protoku 0,5 ml/min a talasna dužina UV detektora iznosi 280 nm. Linearnost (r≥0,999), reproduktivnost (0,68-1,27%), i rikaveri (99,71-101,58) pokazuju zadovoljavajuće vrednosti. Hromatografska analiza je pokazala da se kao glavni proizvod degradacije karvedilola javlja 4-hidroksikarbazol, dok nečistoća C nije prisutna pod ovim uslovima. Predložena RP-HPLC metoda je brza, precizna, tačna, osetljiva, pouzdana i primenljiva za kvalitativnu i kvantitativnu analizu KarvileksR tablete, kao i za praćenje stabilnosti ovog leka.",
publisher = "Srpsko hemijsko društvo, Beograd",
journal = "Journal of the Serbian Chemical Society",
title = "Monitoring of the photochemical stability of carvedilol and its degradation products by the RP-HPLC method, Praćenje fotohemijske stabilnosti karvedilola i njegovih degradacionih proizvoda RP-HPLC metodom",
volume = "72",
number = "1",
pages = "37-44",
doi = "10.2298/JSC0701037S"
}
Stojanović, J., Vladimirov, S., Marinković, V., Veličković, D.,& Sibinović, P.. (2007). Monitoring of the photochemical stability of carvedilol and its degradation products by the RP-HPLC method. in Journal of the Serbian Chemical Society
Srpsko hemijsko društvo, Beograd., 72(1), 37-44.
https://doi.org/10.2298/JSC0701037S
Stojanović J, Vladimirov S, Marinković V, Veličković D, Sibinović P. Monitoring of the photochemical stability of carvedilol and its degradation products by the RP-HPLC method. in Journal of the Serbian Chemical Society. 2007;72(1):37-44.
doi:10.2298/JSC0701037S .
Stojanović, Jelena, Vladimirov, Sote, Marinković, Valentina, Veličković, Dragan, Sibinović, Predrag, "Monitoring of the photochemical stability of carvedilol and its degradation products by the RP-HPLC method" in Journal of the Serbian Chemical Society, 72, no. 1 (2007):37-44,
https://doi.org/10.2298/JSC0701037S . .
16
21
25