Stojković, A

Link to this page

Authority KeyName Variants
10115582-b82e-40c8-8e47-29e7c0de834b
  • Stojković, A (1)
Projects
No records found.

Author's Bibliography

Validation of a high-performance liquid chromatography method for the determination of pancuronium in Pavulon injections

Zečević, Mira; Živanović, L; Stojković, A

(Elsevier Science BV, Amsterdam, 2002)

TY  - JOUR
AU  - Zečević, Mira
AU  - Živanović, L
AU  - Stojković, A
PY  - 2002
UR  - https://farfar.pharmacy.bg.ac.rs/handle/123456789/327
AB  - A new high-performance liquid chromatography (HPLC) method was developed for the quality control of pancuronium bromide and its degradation products. The HPLC method used a 5-mum Supelcogel ODP-50 (150X4 cm) column with acetonitrile-CH3OH-water-F3CCOOH (20.5:74.9:0.1, v/v) as the mobile phase (pH value 2.0 adjusted with trifluoroacetic acid) at a flow-rate 0.8 ml/min and UV detection at 210 nm. The Beer's law plots were found to be linear over the concentration range 0.4-1.2 mg/ml of pancuronium bromide and 0.04-0.08 mg/ml of desacetyl degradation products (R-2=0.9995). The RSD of the peak areas was 1.09% and the recovery was 102.43%. The RSD value shows good precision, acceptable accuracy and reproducibility of the new method for the determination of pancuronium bromide in presence of its desacetyl degradation products. The method is rapid and sensitive enough to be used for Pavulon injection analysis. 2002 Elsevier Science B.V. All rights reserved.
PB  - Elsevier Science BV, Amsterdam
T2  - Journal of Chromatography A
T1  - Validation of a high-performance liquid chromatography method for the determination of pancuronium in Pavulon injections
VL  - 949
IS  - 1-2
SP  - 61
EP  - 64
DO  - 10.1016/S0021-9673(01)01552-7
ER  - 
@article{
author = "Zečević, Mira and Živanović, L and Stojković, A",
year = "2002",
abstract = "A new high-performance liquid chromatography (HPLC) method was developed for the quality control of pancuronium bromide and its degradation products. The HPLC method used a 5-mum Supelcogel ODP-50 (150X4 cm) column with acetonitrile-CH3OH-water-F3CCOOH (20.5:74.9:0.1, v/v) as the mobile phase (pH value 2.0 adjusted with trifluoroacetic acid) at a flow-rate 0.8 ml/min and UV detection at 210 nm. The Beer's law plots were found to be linear over the concentration range 0.4-1.2 mg/ml of pancuronium bromide and 0.04-0.08 mg/ml of desacetyl degradation products (R-2=0.9995). The RSD of the peak areas was 1.09% and the recovery was 102.43%. The RSD value shows good precision, acceptable accuracy and reproducibility of the new method for the determination of pancuronium bromide in presence of its desacetyl degradation products. The method is rapid and sensitive enough to be used for Pavulon injection analysis. 2002 Elsevier Science B.V. All rights reserved.",
publisher = "Elsevier Science BV, Amsterdam",
journal = "Journal of Chromatography A",
title = "Validation of a high-performance liquid chromatography method for the determination of pancuronium in Pavulon injections",
volume = "949",
number = "1-2",
pages = "61-64",
doi = "10.1016/S0021-9673(01)01552-7"
}
Zečević, M., Živanović, L.,& Stojković, A.. (2002). Validation of a high-performance liquid chromatography method for the determination of pancuronium in Pavulon injections. in Journal of Chromatography A
Elsevier Science BV, Amsterdam., 949(1-2), 61-64.
https://doi.org/10.1016/S0021-9673(01)01552-7
Zečević M, Živanović L, Stojković A. Validation of a high-performance liquid chromatography method for the determination of pancuronium in Pavulon injections. in Journal of Chromatography A. 2002;949(1-2):61-64.
doi:10.1016/S0021-9673(01)01552-7 .
Zečević, Mira, Živanović, L, Stojković, A, "Validation of a high-performance liquid chromatography method for the determination of pancuronium in Pavulon injections" in Journal of Chromatography A, 949, no. 1-2 (2002):61-64,
https://doi.org/10.1016/S0021-9673(01)01552-7 . .
20
17
21