Stanković, Aleksandra M.

Link to this page

Authority KeyName Variants
fbe4fd2d-5812-49df-bd8b-1dfbc21db1ac
  • Stanković, Aleksandra M. (1)
Projects

Author's Bibliography

Liquid chromatography/tandem mass spectrometry for simultaneous determination of undeclared corticosteroids in cosmetic creams

Golubović, Jelena; Otašević, Biljana; Protić, Ana; Stanković, Aleksandra M.; Zečević, Mira

(Wiley, Hoboken, 2015)

TY  - JOUR
AU  - Golubović, Jelena
AU  - Otašević, Biljana
AU  - Protić, Ana
AU  - Stanković, Aleksandra M.
AU  - Zečević, Mira
PY  - 2015
UR  - https://farfar.pharmacy.bg.ac.rs/handle/123456789/2303
AB  - RationaleUndeclared corticosteroids in creams intended for frequent use might cause serious side-effects, especially in children. In order to prevent this or find the cause, it was essential to develop a method for quick detection and quantification of low levels of corticosteroids. MethodsEleven corticosteroids were used in this study: prednisolone, methylprednisolone, prednisolone-21-acetate, fluocinolone acetonide, fluocinolone acetonide-21-acetate, hydrocortisone-21-acetate, dexamethasone, betamethasone, betamethasone dipropionate, clobetasol propionate and triamcinolone. Separation was achieved via liquid chromatography (LC), and mass spectrometric analysis was conducted by electrospray ionization triple-quadrupole mass spectrometry (MS/MS) in the multiple reaction monitoring mode using corticosterone as internal standard. ResultsGood separation by using a gradient-elution LC/MS/MS method with run time of 25min enabled the use of a segmented detection method and consecutive decrease in detection limits. The proposed method has been validated in the linearity range of 10-1000ng/mL with coefficients of determination higher than 0.990. The method has shown to have very low limits of quantification (0.75-3ng/mL) with satisfactory precision and accuracy for each of the corticosteroids. ConclusionsAn LC/MS/MS method for the rapid and simultaneous determination of low levels of eleven topical corticosteroids in creams was developed, optimized and validated. The proposed method can be used for testing of different products indicated for the treatment of atopic dermatitis, including "natural products", and "herbal creams" with "miraculous effects". Copyright
PB  - Wiley, Hoboken
T2  - Rapid Communications in Mass Spectrometry
T1  - Liquid chromatography/tandem mass spectrometry for simultaneous determination of undeclared corticosteroids in cosmetic creams
VL  - 29
IS  - 24
SP  - 2319
EP  - 2327
DO  - 10.1002/rcm.7403
ER  - 
@article{
author = "Golubović, Jelena and Otašević, Biljana and Protić, Ana and Stanković, Aleksandra M. and Zečević, Mira",
year = "2015",
abstract = "RationaleUndeclared corticosteroids in creams intended for frequent use might cause serious side-effects, especially in children. In order to prevent this or find the cause, it was essential to develop a method for quick detection and quantification of low levels of corticosteroids. MethodsEleven corticosteroids were used in this study: prednisolone, methylprednisolone, prednisolone-21-acetate, fluocinolone acetonide, fluocinolone acetonide-21-acetate, hydrocortisone-21-acetate, dexamethasone, betamethasone, betamethasone dipropionate, clobetasol propionate and triamcinolone. Separation was achieved via liquid chromatography (LC), and mass spectrometric analysis was conducted by electrospray ionization triple-quadrupole mass spectrometry (MS/MS) in the multiple reaction monitoring mode using corticosterone as internal standard. ResultsGood separation by using a gradient-elution LC/MS/MS method with run time of 25min enabled the use of a segmented detection method and consecutive decrease in detection limits. The proposed method has been validated in the linearity range of 10-1000ng/mL with coefficients of determination higher than 0.990. The method has shown to have very low limits of quantification (0.75-3ng/mL) with satisfactory precision and accuracy for each of the corticosteroids. ConclusionsAn LC/MS/MS method for the rapid and simultaneous determination of low levels of eleven topical corticosteroids in creams was developed, optimized and validated. The proposed method can be used for testing of different products indicated for the treatment of atopic dermatitis, including "natural products", and "herbal creams" with "miraculous effects". Copyright",
publisher = "Wiley, Hoboken",
journal = "Rapid Communications in Mass Spectrometry",
title = "Liquid chromatography/tandem mass spectrometry for simultaneous determination of undeclared corticosteroids in cosmetic creams",
volume = "29",
number = "24",
pages = "2319-2327",
doi = "10.1002/rcm.7403"
}
Golubović, J., Otašević, B., Protić, A., Stanković, A. M.,& Zečević, M.. (2015). Liquid chromatography/tandem mass spectrometry for simultaneous determination of undeclared corticosteroids in cosmetic creams. in Rapid Communications in Mass Spectrometry
Wiley, Hoboken., 29(24), 2319-2327.
https://doi.org/10.1002/rcm.7403
Golubović J, Otašević B, Protić A, Stanković AM, Zečević M. Liquid chromatography/tandem mass spectrometry for simultaneous determination of undeclared corticosteroids in cosmetic creams. in Rapid Communications in Mass Spectrometry. 2015;29(24):2319-2327.
doi:10.1002/rcm.7403 .
Golubović, Jelena, Otašević, Biljana, Protić, Ana, Stanković, Aleksandra M., Zečević, Mira, "Liquid chromatography/tandem mass spectrometry for simultaneous determination of undeclared corticosteroids in cosmetic creams" in Rapid Communications in Mass Spectrometry, 29, no. 24 (2015):2319-2327,
https://doi.org/10.1002/rcm.7403 . .
2
18
15
20