Živanović, Slavoljub

Link to this page

Authority KeyName Variants
b38a63dc-8630-4187-b575-cd5cdb9defc4
  • Živanović, Slavoljub (1)
Projects

Author's Bibliography

Development and validation of a solid phase extraction-HPLC method for the determination of carbamazepine and its metabolites, carbamazepine epoxide and carbamazepine trans-diol, in plasma

Džodić, Predrag; Živanović, Ljiljana; Protić, Ana; Ivanović, Ivana; Veličković-Radovanović, Radmila; Spasić, Mirjana; Lukić, Stevo; Živanović, Slavoljub

(Srpsko hemijsko društvo, Beograd, 2012)

TY  - JOUR
AU  - Džodić, Predrag
AU  - Živanović, Ljiljana
AU  - Protić, Ana
AU  - Ivanović, Ivana
AU  - Veličković-Radovanović, Radmila
AU  - Spasić, Mirjana
AU  - Lukić, Stevo
AU  - Živanović, Slavoljub
PY  - 2012
UR  - https://farfar.pharmacy.bg.ac.rs/handle/123456789/1823
AB  - A solid phase extraction-HPLC method has been developed and validated for the rapid analysis of carbamazepine and its two metabolites, carbamazepine epoxide and carbamazepine trans-diol, in human plasma. The analysis was performed using a C18 Bakerbond-BDC analytical column (250 mm×4.6 mm i.d., particle size 5 μm). The optimal conditions for the separation were established with the mobile phase acetonitrile - 10 mM phosphate buffer, pH 7.0 (30:70, v/v) at a flow rate of 1.5 mL min-1 and temperature of 35°C, with UV detection at 210 nm. The total run time was about 8 minutes. The SPE procedure for the extraction of the analytes from a plasma sample was developed using Oasis HLB cartridges and subsequently, the eluate was injected into the HPLC system for analysis. Afterwards, the SPE-HPLC method was subjected to validation. Linearity was obtained over the concentration range of 0.2-25 μg mL-1 for carbamazepine, carbamazepine epoxide and carbamazepine trans-diol, with correlation coefficients higher than 0.995. The method showed good intra-day and inter-day precision with a relative standard deviation below 7.96 %, while the accuracy ranged from 92.09 to 108.5 % for all analytes. Finally, the method was successfully applied to the analysis of the plasma samples of epileptic patients in mono- and polytherapy.
AB  - SPE-HPLC metoda je razvijena i validirana u cilju brzog analiziranja karbamazepina i metabolita karbamazepin epoksida i karbamazepin trans-diola u humanoj plazmi. C18 Bakerbond-BDC analitička kolona (250 mm x 4,6 mm; 5 μm) je korišćena radi izvođenja analize. Optimalni uslovi za hromatografsko razdvajanje su mobilna faza acetonitril - 10 mM fosfatni pufer, pH 7,0 (30:70, v/v), protok od 1,5 ml min-1, temperatura 35°C i detekcija na 210 nm. Ukupno trajanje hromatografskog rana iznosi oko 8 min. SPE procedura za ekstrakciju analita iz uzoraka plazme je razvijena uz korišćenje Oasis HLB ketridža nakon čega se eluat injektuje u HPLC sistem radi analiziranja. Zatim je izvršena validacija SPE-HPLC metode. Linearnost je potvrđena u koncentracionom opsegu 0,2-25 μg/ml za karbamazepin, karbamazepin epoksid i karbamazepin trans-diol sa vrednošću korelacionih koeficijenata višom od 0,995. Preciznost metode u toku jednog i u toku više dana je dobra sa relativnom standardnom devijacijom nižom od 7,96 %, dok tačnost metode obuhvata vrednosti u opsegu od 92,09 do 108,5 % za sve analite. Na kraju je metoda uspešno primenjena u cilju analiziranja uzoraka plazme pacijenata obolelih od epilepsije na monoterapiji i politerapiji.
PB  - Srpsko hemijsko društvo, Beograd
T2  - Journal of the Serbian Chemical Society
T1  - Development and validation of a solid phase extraction-HPLC method for the determination of carbamazepine and its metabolites, carbamazepine epoxide and carbamazepine trans-diol, in plasma
T1  - Razvoj i validacija spe-HPLC metode za određivanje karbamazepina i metabolita karbamazepin epoksida i karbamazepin trans-diola u plazmi
VL  - 77
IS  - 10
SP  - 1423
EP  - 1436
DO  - 10.2298/JSC120106084D
ER  - 
@article{
author = "Džodić, Predrag and Živanović, Ljiljana and Protić, Ana and Ivanović, Ivana and Veličković-Radovanović, Radmila and Spasić, Mirjana and Lukić, Stevo and Živanović, Slavoljub",
year = "2012",
abstract = "A solid phase extraction-HPLC method has been developed and validated for the rapid analysis of carbamazepine and its two metabolites, carbamazepine epoxide and carbamazepine trans-diol, in human plasma. The analysis was performed using a C18 Bakerbond-BDC analytical column (250 mm×4.6 mm i.d., particle size 5 μm). The optimal conditions for the separation were established with the mobile phase acetonitrile - 10 mM phosphate buffer, pH 7.0 (30:70, v/v) at a flow rate of 1.5 mL min-1 and temperature of 35°C, with UV detection at 210 nm. The total run time was about 8 minutes. The SPE procedure for the extraction of the analytes from a plasma sample was developed using Oasis HLB cartridges and subsequently, the eluate was injected into the HPLC system for analysis. Afterwards, the SPE-HPLC method was subjected to validation. Linearity was obtained over the concentration range of 0.2-25 μg mL-1 for carbamazepine, carbamazepine epoxide and carbamazepine trans-diol, with correlation coefficients higher than 0.995. The method showed good intra-day and inter-day precision with a relative standard deviation below 7.96 %, while the accuracy ranged from 92.09 to 108.5 % for all analytes. Finally, the method was successfully applied to the analysis of the plasma samples of epileptic patients in mono- and polytherapy., SPE-HPLC metoda je razvijena i validirana u cilju brzog analiziranja karbamazepina i metabolita karbamazepin epoksida i karbamazepin trans-diola u humanoj plazmi. C18 Bakerbond-BDC analitička kolona (250 mm x 4,6 mm; 5 μm) je korišćena radi izvođenja analize. Optimalni uslovi za hromatografsko razdvajanje su mobilna faza acetonitril - 10 mM fosfatni pufer, pH 7,0 (30:70, v/v), protok od 1,5 ml min-1, temperatura 35°C i detekcija na 210 nm. Ukupno trajanje hromatografskog rana iznosi oko 8 min. SPE procedura za ekstrakciju analita iz uzoraka plazme je razvijena uz korišćenje Oasis HLB ketridža nakon čega se eluat injektuje u HPLC sistem radi analiziranja. Zatim je izvršena validacija SPE-HPLC metode. Linearnost je potvrđena u koncentracionom opsegu 0,2-25 μg/ml za karbamazepin, karbamazepin epoksid i karbamazepin trans-diol sa vrednošću korelacionih koeficijenata višom od 0,995. Preciznost metode u toku jednog i u toku više dana je dobra sa relativnom standardnom devijacijom nižom od 7,96 %, dok tačnost metode obuhvata vrednosti u opsegu od 92,09 do 108,5 % za sve analite. Na kraju je metoda uspešno primenjena u cilju analiziranja uzoraka plazme pacijenata obolelih od epilepsije na monoterapiji i politerapiji.",
publisher = "Srpsko hemijsko društvo, Beograd",
journal = "Journal of the Serbian Chemical Society",
title = "Development and validation of a solid phase extraction-HPLC method for the determination of carbamazepine and its metabolites, carbamazepine epoxide and carbamazepine trans-diol, in plasma, Razvoj i validacija spe-HPLC metode za određivanje karbamazepina i metabolita karbamazepin epoksida i karbamazepin trans-diola u plazmi",
volume = "77",
number = "10",
pages = "1423-1436",
doi = "10.2298/JSC120106084D"
}
Džodić, P., Živanović, L., Protić, A., Ivanović, I., Veličković-Radovanović, R., Spasić, M., Lukić, S.,& Živanović, S.. (2012). Development and validation of a solid phase extraction-HPLC method for the determination of carbamazepine and its metabolites, carbamazepine epoxide and carbamazepine trans-diol, in plasma. in Journal of the Serbian Chemical Society
Srpsko hemijsko društvo, Beograd., 77(10), 1423-1436.
https://doi.org/10.2298/JSC120106084D
Džodić P, Živanović L, Protić A, Ivanović I, Veličković-Radovanović R, Spasić M, Lukić S, Živanović S. Development and validation of a solid phase extraction-HPLC method for the determination of carbamazepine and its metabolites, carbamazepine epoxide and carbamazepine trans-diol, in plasma. in Journal of the Serbian Chemical Society. 2012;77(10):1423-1436.
doi:10.2298/JSC120106084D .
Džodić, Predrag, Živanović, Ljiljana, Protić, Ana, Ivanović, Ivana, Veličković-Radovanović, Radmila, Spasić, Mirjana, Lukić, Stevo, Živanović, Slavoljub, "Development and validation of a solid phase extraction-HPLC method for the determination of carbamazepine and its metabolites, carbamazepine epoxide and carbamazepine trans-diol, in plasma" in Journal of the Serbian Chemical Society, 77, no. 10 (2012):1423-1436,
https://doi.org/10.2298/JSC120106084D . .
9
10
12