Dmitrašinović, Gordana

Link to this page

Authority KeyName Variants
orcid::0000-0001-9348-6625
  • Dmitrašinović, Gordana (4)
Projects

Author's Bibliography

Analitičke i kliničke karakteristike seroloških imonoodređivanja anti-SARS-CoV-2 antitela

Milinković, Neda; Sarić-Matutinović, Marija; Tadić, Ivana; Dmitrašinović, Gordana; Ignjatović, Svetlana

(Udruženje farmaceuta Beograd, 2022)

TY  - CONF
AU  - Milinković, Neda
AU  - Sarić-Matutinović, Marija
AU  - Tadić, Ivana
AU  - Dmitrašinović, Gordana
AU  - Ignjatović, Svetlana
PY  - 2022
UR  - https://farfar.pharmacy.bg.ac.rs/handle/123456789/5591
AB  - Uvod i cilj. Literaturni podaci ukazuju da serološka imunoodređivanja mogu biti adekvatna
dopuna molekularnoj dijagnostici SARS-CoV-2 infekcije. Cilj ovog ispitivanja je da se proceni
slaganje SARS-CoV-2 seroloških testova pet različitih proizvođača i ispita imuni odgovor na
različite vrste vakcina.
Metode. Korišćene su metode: Sars-CoV-2 IgG (Beckman Coulter) (I), SARS-CoV-2 ukupna
antitela (BioRad) (II), SARS-CoV-2 IgG II Quant (Abbott) (III), SARS-CoV-2 IgG (Abbott) (IV) i
Elecsys Anti-SARS-CoV-2 (Roche) (V). Paralelno je ispitivano metodom I i II 44 uzorka, I i III 84
uzorka, I i IV 53 uzorka, I i V 80 uzoraka. Dodatno je za procenu imunog odgovora na infekciju i
različite vrste vakcina analizirano 153 uzorka. Ispitanici su proveravali prisustvo antitela zbog
sumnje na asimptomatsku SARS-CoV-2 infekciju ili zbog prisustva simptoma.
Rezultati. II i III metodom je dobijen značajno veći broj reaktivnih rezultata u odnosu na I
metod (65,9% i 91,7% vs 52,3%). I i IV metode su pokazale slaganje u reaktivnosti (60,4% vs
69,8%), dok I i V metodom nije dobijeno slaganje u reaktivnosti rezultata (58,8% vs 93,8%).
Najintenzivniji imuni odgovor postignut je nakon vakcinacije Phizer vakcinom. Imuni odgovor
nakon Phizer i Sinopharm vakcine je pokazao značajnu korelaciju sa vremenom proteklim od
imunizacije (P=0,032 i P=0,012). Žene su imale značajno viši titar antitela nakon vakcinacije
u odnosu na muškarce (P=0,006). Nije dobijena značajna razlika u odnosu na tip vakcine i
godina starosti ispitanika (P=0,197).
Zaključak
Iako serološka imunoodređivanja pokazuju značajne analitičke i kliničke karakteristike za
detekciju SARS-CoV-2 i dalje postoji problem kompletne evaluacije testova i neizvesnosti u
pogledu tačnosti rezultata i njihove uporedivosti.
PB  - Udruženje farmaceuta Beograd
C3  - Simpozijum "Covid-19 infekcija-dijagnostički i prognostički biohemijski parametri", Program i zbornik sažetaka, 18.03.2022, Beograd
T1  - Analitičke i kliničke karakteristike seroloških imonoodređivanja anti-SARS-CoV-2 antitela
SP  - 12
EP  - 12
UR  - https://hdl.handle.net/21.15107/rcub_farfar_5591
ER  - 
@conference{
author = "Milinković, Neda and Sarić-Matutinović, Marija and Tadić, Ivana and Dmitrašinović, Gordana and Ignjatović, Svetlana",
year = "2022",
abstract = "Uvod i cilj. Literaturni podaci ukazuju da serološka imunoodređivanja mogu biti adekvatna
dopuna molekularnoj dijagnostici SARS-CoV-2 infekcije. Cilj ovog ispitivanja je da se proceni
slaganje SARS-CoV-2 seroloških testova pet različitih proizvođača i ispita imuni odgovor na
različite vrste vakcina.
Metode. Korišćene su metode: Sars-CoV-2 IgG (Beckman Coulter) (I), SARS-CoV-2 ukupna
antitela (BioRad) (II), SARS-CoV-2 IgG II Quant (Abbott) (III), SARS-CoV-2 IgG (Abbott) (IV) i
Elecsys Anti-SARS-CoV-2 (Roche) (V). Paralelno je ispitivano metodom I i II 44 uzorka, I i III 84
uzorka, I i IV 53 uzorka, I i V 80 uzoraka. Dodatno je za procenu imunog odgovora na infekciju i
različite vrste vakcina analizirano 153 uzorka. Ispitanici su proveravali prisustvo antitela zbog
sumnje na asimptomatsku SARS-CoV-2 infekciju ili zbog prisustva simptoma.
Rezultati. II i III metodom je dobijen značajno veći broj reaktivnih rezultata u odnosu na I
metod (65,9% i 91,7% vs 52,3%). I i IV metode su pokazale slaganje u reaktivnosti (60,4% vs
69,8%), dok I i V metodom nije dobijeno slaganje u reaktivnosti rezultata (58,8% vs 93,8%).
Najintenzivniji imuni odgovor postignut je nakon vakcinacije Phizer vakcinom. Imuni odgovor
nakon Phizer i Sinopharm vakcine je pokazao značajnu korelaciju sa vremenom proteklim od
imunizacije (P=0,032 i P=0,012). Žene su imale značajno viši titar antitela nakon vakcinacije
u odnosu na muškarce (P=0,006). Nije dobijena značajna razlika u odnosu na tip vakcine i
godina starosti ispitanika (P=0,197).
Zaključak
Iako serološka imunoodređivanja pokazuju značajne analitičke i kliničke karakteristike za
detekciju SARS-CoV-2 i dalje postoji problem kompletne evaluacije testova i neizvesnosti u
pogledu tačnosti rezultata i njihove uporedivosti.",
publisher = "Udruženje farmaceuta Beograd",
journal = "Simpozijum "Covid-19 infekcija-dijagnostički i prognostički biohemijski parametri", Program i zbornik sažetaka, 18.03.2022, Beograd",
title = "Analitičke i kliničke karakteristike seroloških imonoodređivanja anti-SARS-CoV-2 antitela",
pages = "12-12",
url = "https://hdl.handle.net/21.15107/rcub_farfar_5591"
}
Milinković, N., Sarić-Matutinović, M., Tadić, I., Dmitrašinović, G.,& Ignjatović, S.. (2022). Analitičke i kliničke karakteristike seroloških imonoodređivanja anti-SARS-CoV-2 antitela. in Simpozijum "Covid-19 infekcija-dijagnostički i prognostički biohemijski parametri", Program i zbornik sažetaka, 18.03.2022, Beograd
Udruženje farmaceuta Beograd., 12-12.
https://hdl.handle.net/21.15107/rcub_farfar_5591
Milinković N, Sarić-Matutinović M, Tadić I, Dmitrašinović G, Ignjatović S. Analitičke i kliničke karakteristike seroloških imonoodređivanja anti-SARS-CoV-2 antitela. in Simpozijum "Covid-19 infekcija-dijagnostički i prognostički biohemijski parametri", Program i zbornik sažetaka, 18.03.2022, Beograd. 2022;:12-12.
https://hdl.handle.net/21.15107/rcub_farfar_5591 .
Milinković, Neda, Sarić-Matutinović, Marija, Tadić, Ivana, Dmitrašinović, Gordana, Ignjatović, Svetlana, "Analitičke i kliničke karakteristike seroloških imonoodređivanja anti-SARS-CoV-2 antitela" in Simpozijum "Covid-19 infekcija-dijagnostički i prognostički biohemijski parametri", Program i zbornik sažetaka, 18.03.2022, Beograd (2022):12-12,
https://hdl.handle.net/21.15107/rcub_farfar_5591 .

Dijagnostičke karakteristike serološkog access SARS-CoV-2 IgG imunohemijskog testa

Sarić-Matutinović, Marija; Milinković, Neda; Dmitrašinović, Gordana; Ignjatović, Svetlana

(Udruženje farmaceuta Beograd, 2022)

TY  - CONF
AU  - Sarić-Matutinović, Marija
AU  - Milinković, Neda
AU  - Dmitrašinović, Gordana
AU  - Ignjatović, Svetlana
PY  - 2022
UR  - https://farfar.pharmacy.bg.ac.rs/handle/123456789/5590
AB  - Uvod i cilj. Pandemija bolesti izazvane teškim akutnim respiratornim sindromom korona-
virus 2 (SARS-CoV-2) dovela je do ekspanzije seroloških testova za određivanje antitela i an-
tigena virusa. Access SARS-CoV-2 IgG je serološki test namenjen je za detekciju IgG antitela
virusa, i može se koristiti kao dodatno sredstvo prilikom detekcije patogena, praćenja stanja
pacijenata, procene imuniteta nakon infekcije i vakcinacije. Cilj istraživanja je bio da se odre-
de dijagnostičke karakteristike i klinički značaj Access SARS-CoV-2 IgG testa.
Metode. Istraživanjem je obuhvaćeno 94 ispitanika sa potvrđenom prethodnom SARS-
CoV-2 infekcijom (PCR metodom) i 104 kontrolna ispitanika. IgG antitela su određena u se-
rumu ispitanika primenom Access Sars-CoV-2 IgG testa, proizvođača Beckman Coulter, na
imunohemijskom Access 2 imunoanalizatoru iste firme.
Rezultati. Titar IgG antitela je bio značajno veći kod ispitanika koji su preležali infekciju
(3,95 (1,36 - 11,44 S/CO) u odnosu na kontrolne ispitanike (0,03 (0,02 – 0,16 S/CO) (p <
0,001). ROC analizom je utvrđena statistički značajna AUC (0,946, p < 0,001), a osetljivost i
specifičnost za potvrdu infekcije su redom bile 81% i 95%, za graničnu vrednost 0,955. Pozitiv-
na i negativna prediktivna vrednost su bile 94% i 85%, redom. Dodatno je utvrđeno da je titar
IgG antitela bio najveći u grupi ispitanika sa teškim oblikom infekcije, u poređenju sa ispita-
nicima koji su imali lakši oblik i ispitanicima koji su imali blagu ili asimptomatsku infekciju (p
= 0,048).
Zaključak. Naši rezultati ukazuju na to da analizirani Access SARS-CoV-2 IgG serološki
test ima zadovoljavajuće dijagnostičke karakteristike i može biti klinički značajan za procenu
stanja imuniteta nakon preležane infekcije.
PB  - Udruženje farmaceuta Beograd
C3  - Simpozijum "Covid-19 infekcija-dijagnostički i prognostički biohemijski parametri", Program i zbornik sažetaka, 18.03.2022, Beograd
T1  - Dijagnostičke karakteristike serološkog access SARS-CoV-2 IgG imunohemijskog testa
SP  - 20
EP  - 20
UR  - https://hdl.handle.net/21.15107/rcub_farfar_5590
ER  - 
@conference{
author = "Sarić-Matutinović, Marija and Milinković, Neda and Dmitrašinović, Gordana and Ignjatović, Svetlana",
year = "2022",
abstract = "Uvod i cilj. Pandemija bolesti izazvane teškim akutnim respiratornim sindromom korona-
virus 2 (SARS-CoV-2) dovela je do ekspanzije seroloških testova za određivanje antitela i an-
tigena virusa. Access SARS-CoV-2 IgG je serološki test namenjen je za detekciju IgG antitela
virusa, i može se koristiti kao dodatno sredstvo prilikom detekcije patogena, praćenja stanja
pacijenata, procene imuniteta nakon infekcije i vakcinacije. Cilj istraživanja je bio da se odre-
de dijagnostičke karakteristike i klinički značaj Access SARS-CoV-2 IgG testa.
Metode. Istraživanjem je obuhvaćeno 94 ispitanika sa potvrđenom prethodnom SARS-
CoV-2 infekcijom (PCR metodom) i 104 kontrolna ispitanika. IgG antitela su određena u se-
rumu ispitanika primenom Access Sars-CoV-2 IgG testa, proizvođača Beckman Coulter, na
imunohemijskom Access 2 imunoanalizatoru iste firme.
Rezultati. Titar IgG antitela je bio značajno veći kod ispitanika koji su preležali infekciju
(3,95 (1,36 - 11,44 S/CO) u odnosu na kontrolne ispitanike (0,03 (0,02 – 0,16 S/CO) (p <
0,001). ROC analizom je utvrđena statistički značajna AUC (0,946, p < 0,001), a osetljivost i
specifičnost za potvrdu infekcije su redom bile 81% i 95%, za graničnu vrednost 0,955. Pozitiv-
na i negativna prediktivna vrednost su bile 94% i 85%, redom. Dodatno je utvrđeno da je titar
IgG antitela bio najveći u grupi ispitanika sa teškim oblikom infekcije, u poređenju sa ispita-
nicima koji su imali lakši oblik i ispitanicima koji su imali blagu ili asimptomatsku infekciju (p
= 0,048).
Zaključak. Naši rezultati ukazuju na to da analizirani Access SARS-CoV-2 IgG serološki
test ima zadovoljavajuće dijagnostičke karakteristike i može biti klinički značajan za procenu
stanja imuniteta nakon preležane infekcije.",
publisher = "Udruženje farmaceuta Beograd",
journal = "Simpozijum "Covid-19 infekcija-dijagnostički i prognostički biohemijski parametri", Program i zbornik sažetaka, 18.03.2022, Beograd",
title = "Dijagnostičke karakteristike serološkog access SARS-CoV-2 IgG imunohemijskog testa",
pages = "20-20",
url = "https://hdl.handle.net/21.15107/rcub_farfar_5590"
}
Sarić-Matutinović, M., Milinković, N., Dmitrašinović, G.,& Ignjatović, S.. (2022). Dijagnostičke karakteristike serološkog access SARS-CoV-2 IgG imunohemijskog testa. in Simpozijum "Covid-19 infekcija-dijagnostički i prognostički biohemijski parametri", Program i zbornik sažetaka, 18.03.2022, Beograd
Udruženje farmaceuta Beograd., 20-20.
https://hdl.handle.net/21.15107/rcub_farfar_5590
Sarić-Matutinović M, Milinković N, Dmitrašinović G, Ignjatović S. Dijagnostičke karakteristike serološkog access SARS-CoV-2 IgG imunohemijskog testa. in Simpozijum "Covid-19 infekcija-dijagnostički i prognostički biohemijski parametri", Program i zbornik sažetaka, 18.03.2022, Beograd. 2022;:20-20.
https://hdl.handle.net/21.15107/rcub_farfar_5590 .
Sarić-Matutinović, Marija, Milinković, Neda, Dmitrašinović, Gordana, Ignjatović, Svetlana, "Dijagnostičke karakteristike serološkog access SARS-CoV-2 IgG imunohemijskog testa" in Simpozijum "Covid-19 infekcija-dijagnostički i prognostički biohemijski parametri", Program i zbornik sažetaka, 18.03.2022, Beograd (2022):20-20,
https://hdl.handle.net/21.15107/rcub_farfar_5590 .

Compliance of the POCT method with the fully automated method for HbA1c determination

Milinković, Neda; Sarić-Matutinović, Marija; Dmitrašinović, Gordana; Ignjatović, Svetlana

(Pharmaceutical Association of Serbia, 2022)

TY  - JOUR
AU  - Milinković, Neda
AU  - Sarić-Matutinović, Marija
AU  - Dmitrašinović, Gordana
AU  - Ignjatović, Svetlana
PY  - 2022
UR  - https://farfar.pharmacy.bg.ac.rs/handle/123456789/4242
AB  - Previous research suggests that point-of-care (POCT) determination of glycated hemoglobin (HbA1c) is a diagnostic test that can be an adequate alternative to measuring HbA1c in the laboratory. The main goal of this study was to examine the analytical characteristics of the novel INCLIX POCT method for HbA1c determination in order to test its performance before introducing this method into routine use. HbA1c is measured in a duplicate in 44 EDTA blood samples parallel on INCLIX POCT device (Sugitech, Inc.) and using automated turbidimetric immunoinhibition test on Olympus AU400 (Beckman Coulter). The within run imprecision was 7.58%, between runs imprecision was 6.63% and 6.22%, and day-to-day imprecision was 8.80% and 7.51%. Total laboratory imprecision was in agreement with those stated by the manufacturer. A statistically significant Pearson correlation coefficient was calculated (r = 0.871, P < 0.01; linear R2 = 0.757). Using Deming regression analysis, the following equation was obtained: y = - 1.80 + 1.304x. Our results indicate statistically significant correlation, linear relationship, and a significant degree of compatibility between the two analyzed methods. However, the negative bias of the HbA1c values determined on the POCT analyzer compared to the Olympus AU400 was confirmed, highlighting the need to standardize the INCLIX method.
AB  - Prethodna istraživanja sugerišu da je „point-of-care“ metoda (POCT) za određivanje glikoziliranog hemoglobina (HbA1c) dijagnostički test koji može biti adekvatna alternativa merenju HbA1c u laboratoriji. Glavni cilj ovog istraživanja bio je da se ispitaju analitičke karakteristike nove INCLIX POCT metode za određivanje HbA1c kako bi se testirale karakteristike izvođenja pre uvođenja ove metode u rutinsku upotrebu. HbA1c je meren u duplikatu u 44 uzorka EDTA krvi paralelno na INCLIX POCT uređaju (Sugitech, Inc.) i automatskim turbidimetrijskim imunoinhibicijskim testom na Olympus AU400 biohemijskom analizatoru (Beckman Coulter). Nepreciznost u seriji bila je 7,58%, nepreciznost između serija bila je 6,63% i 6,22%, a nepreciznost iz dana u dan bila je 8,80% i 7,51%. Ukupna laboratorijska nepreciznost bila je u slaganju sa podacima koje je naveo proizvođač. Izračunat je statistički značajan Pearsonov koeficijent korelacije (r = 0,871, P < 0,01; linearni R2 = 0,757). Demingovom regresionom analizom dobijena je sledeća jednačina: y = -1,80 + 1,304x. Naši rezultati ukazuju na statistički značajnu korelaciju, linearnu povezanost i značajan stepen kompatibilnosti između dve analizirane metode. Međutim, potvrđen je negativan bias vrednosti HbA1c određenih na POCT analizatoru u odnosu na Olympus AU400, što ističe potrebu za standardizacijom INCLIX metode.
PB  - Pharmaceutical Association of Serbia
T2  - Arhiv za farmaciju
T1  - Compliance of the POCT method with the fully automated method for HbA1c determination
T1  - Usklađenost POCT metode sa potpuno automatizovanom metodom za određivanje HbA1c
VL  - 72
IS  - 1
SP  - 77
EP  - 90
DO  - 10.5937/arhfarm72-35905
ER  - 
@article{
author = "Milinković, Neda and Sarić-Matutinović, Marija and Dmitrašinović, Gordana and Ignjatović, Svetlana",
year = "2022",
abstract = "Previous research suggests that point-of-care (POCT) determination of glycated hemoglobin (HbA1c) is a diagnostic test that can be an adequate alternative to measuring HbA1c in the laboratory. The main goal of this study was to examine the analytical characteristics of the novel INCLIX POCT method for HbA1c determination in order to test its performance before introducing this method into routine use. HbA1c is measured in a duplicate in 44 EDTA blood samples parallel on INCLIX POCT device (Sugitech, Inc.) and using automated turbidimetric immunoinhibition test on Olympus AU400 (Beckman Coulter). The within run imprecision was 7.58%, between runs imprecision was 6.63% and 6.22%, and day-to-day imprecision was 8.80% and 7.51%. Total laboratory imprecision was in agreement with those stated by the manufacturer. A statistically significant Pearson correlation coefficient was calculated (r = 0.871, P < 0.01; linear R2 = 0.757). Using Deming regression analysis, the following equation was obtained: y = - 1.80 + 1.304x. Our results indicate statistically significant correlation, linear relationship, and a significant degree of compatibility between the two analyzed methods. However, the negative bias of the HbA1c values determined on the POCT analyzer compared to the Olympus AU400 was confirmed, highlighting the need to standardize the INCLIX method., Prethodna istraživanja sugerišu da je „point-of-care“ metoda (POCT) za određivanje glikoziliranog hemoglobina (HbA1c) dijagnostički test koji može biti adekvatna alternativa merenju HbA1c u laboratoriji. Glavni cilj ovog istraživanja bio je da se ispitaju analitičke karakteristike nove INCLIX POCT metode za određivanje HbA1c kako bi se testirale karakteristike izvođenja pre uvođenja ove metode u rutinsku upotrebu. HbA1c je meren u duplikatu u 44 uzorka EDTA krvi paralelno na INCLIX POCT uređaju (Sugitech, Inc.) i automatskim turbidimetrijskim imunoinhibicijskim testom na Olympus AU400 biohemijskom analizatoru (Beckman Coulter). Nepreciznost u seriji bila je 7,58%, nepreciznost između serija bila je 6,63% i 6,22%, a nepreciznost iz dana u dan bila je 8,80% i 7,51%. Ukupna laboratorijska nepreciznost bila je u slaganju sa podacima koje je naveo proizvođač. Izračunat je statistički značajan Pearsonov koeficijent korelacije (r = 0,871, P < 0,01; linearni R2 = 0,757). Demingovom regresionom analizom dobijena je sledeća jednačina: y = -1,80 + 1,304x. Naši rezultati ukazuju na statistički značajnu korelaciju, linearnu povezanost i značajan stepen kompatibilnosti između dve analizirane metode. Međutim, potvrđen je negativan bias vrednosti HbA1c određenih na POCT analizatoru u odnosu na Olympus AU400, što ističe potrebu za standardizacijom INCLIX metode.",
publisher = "Pharmaceutical Association of Serbia",
journal = "Arhiv za farmaciju",
title = "Compliance of the POCT method with the fully automated method for HbA1c determination, Usklađenost POCT metode sa potpuno automatizovanom metodom za određivanje HbA1c",
volume = "72",
number = "1",
pages = "77-90",
doi = "10.5937/arhfarm72-35905"
}
Milinković, N., Sarić-Matutinović, M., Dmitrašinović, G.,& Ignjatović, S.. (2022). Compliance of the POCT method with the fully automated method for HbA1c determination. in Arhiv za farmaciju
Pharmaceutical Association of Serbia., 72(1), 77-90.
https://doi.org/10.5937/arhfarm72-35905
Milinković N, Sarić-Matutinović M, Dmitrašinović G, Ignjatović S. Compliance of the POCT method with the fully automated method for HbA1c determination. in Arhiv za farmaciju. 2022;72(1):77-90.
doi:10.5937/arhfarm72-35905 .
Milinković, Neda, Sarić-Matutinović, Marija, Dmitrašinović, Gordana, Ignjatović, Svetlana, "Compliance of the POCT method with the fully automated method for HbA1c determination" in Arhiv za farmaciju, 72, no. 1 (2022):77-90,
https://doi.org/10.5937/arhfarm72-35905 . .

Magnesium Supplementation Diminishes Peripheral Blood Lymphocyte DNA Oxidative Damage in Athletes and Sedentary Young Man

Petrović, Jelena; Stanić, Dušanka; Dmitrašinović, Gordana; Plećaš-Solarović, Bosiljka; Ignjatović, Svetlana; Batinić, Bojan; Popović, Dejana; Pešić, Vesna

(Hindawi Ltd, London, 2016)

TY  - JOUR
AU  - Petrović, Jelena
AU  - Stanić, Dušanka
AU  - Dmitrašinović, Gordana
AU  - Plećaš-Solarović, Bosiljka
AU  - Ignjatović, Svetlana
AU  - Batinić, Bojan
AU  - Popović, Dejana
AU  - Pešić, Vesna
PY  - 2016
UR  - https://farfar.pharmacy.bg.ac.rs/handle/123456789/2557
AB  - Sedentary lifestyle is highly associated with increased risk of cardiovascular disease, obesity, and type 2 diabetes. It is known that regular physical activity has positive effects on health; however several studies have shown that acute and strenuous exercise can induce oxidative stress and lead to DNA damage. As magnesium is essential in maintaining DNA integrity, the aim of this study was to determine whether four-week-long magnesium supplementation in students with sedentary lifestyle and rugby players could prevent or diminish impairment of DNA. By using the comet assay, our study demonstrated that the number of peripheral blood lymphocytes (PBL) with basal endogenous DNA damage is significantly higher in rugby players compared to students with sedentary lifestyle. On the other hand, magnesium supplementation significantly decreased the number of cells with high DNA damage, in the presence of exogenous H2O2, in PBL from both students and rugby players, and markedly reduced the number of cells with medium DNA damage in rugby players compared to corresponding control nonsupplemented group. Accordingly, the results of our study suggest that four-week-long magnesium supplementation has marked effects in protecting the DNA from oxidative damage in both rugby players and in young men with sedentary lifestyle.
PB  - Hindawi Ltd, London
T2  - Oxidative Medicine and Cellular Longevity
T1  - Magnesium Supplementation Diminishes Peripheral Blood Lymphocyte DNA Oxidative Damage in Athletes and Sedentary Young Man
DO  - 10.1155/2016/2019643
ER  - 
@article{
author = "Petrović, Jelena and Stanić, Dušanka and Dmitrašinović, Gordana and Plećaš-Solarović, Bosiljka and Ignjatović, Svetlana and Batinić, Bojan and Popović, Dejana and Pešić, Vesna",
year = "2016",
abstract = "Sedentary lifestyle is highly associated with increased risk of cardiovascular disease, obesity, and type 2 diabetes. It is known that regular physical activity has positive effects on health; however several studies have shown that acute and strenuous exercise can induce oxidative stress and lead to DNA damage. As magnesium is essential in maintaining DNA integrity, the aim of this study was to determine whether four-week-long magnesium supplementation in students with sedentary lifestyle and rugby players could prevent or diminish impairment of DNA. By using the comet assay, our study demonstrated that the number of peripheral blood lymphocytes (PBL) with basal endogenous DNA damage is significantly higher in rugby players compared to students with sedentary lifestyle. On the other hand, magnesium supplementation significantly decreased the number of cells with high DNA damage, in the presence of exogenous H2O2, in PBL from both students and rugby players, and markedly reduced the number of cells with medium DNA damage in rugby players compared to corresponding control nonsupplemented group. Accordingly, the results of our study suggest that four-week-long magnesium supplementation has marked effects in protecting the DNA from oxidative damage in both rugby players and in young men with sedentary lifestyle.",
publisher = "Hindawi Ltd, London",
journal = "Oxidative Medicine and Cellular Longevity",
title = "Magnesium Supplementation Diminishes Peripheral Blood Lymphocyte DNA Oxidative Damage in Athletes and Sedentary Young Man",
doi = "10.1155/2016/2019643"
}
Petrović, J., Stanić, D., Dmitrašinović, G., Plećaš-Solarović, B., Ignjatović, S., Batinić, B., Popović, D.,& Pešić, V.. (2016). Magnesium Supplementation Diminishes Peripheral Blood Lymphocyte DNA Oxidative Damage in Athletes and Sedentary Young Man. in Oxidative Medicine and Cellular Longevity
Hindawi Ltd, London..
https://doi.org/10.1155/2016/2019643
Petrović J, Stanić D, Dmitrašinović G, Plećaš-Solarović B, Ignjatović S, Batinić B, Popović D, Pešić V. Magnesium Supplementation Diminishes Peripheral Blood Lymphocyte DNA Oxidative Damage in Athletes and Sedentary Young Man. in Oxidative Medicine and Cellular Longevity. 2016;.
doi:10.1155/2016/2019643 .
Petrović, Jelena, Stanić, Dušanka, Dmitrašinović, Gordana, Plećaš-Solarović, Bosiljka, Ignjatović, Svetlana, Batinić, Bojan, Popović, Dejana, Pešić, Vesna, "Magnesium Supplementation Diminishes Peripheral Blood Lymphocyte DNA Oxidative Damage in Athletes and Sedentary Young Man" in Oxidative Medicine and Cellular Longevity (2016),
https://doi.org/10.1155/2016/2019643 . .
3
29
14
28