Quantitation of pregabalin in dried blood spots and dried plasma spots by validated LC-MS/MS methods

Kostić, Nada; Dotsikas, Yannis; Jović, Nebojša; Stevanović, Galina; Malenović, Anđelija; Medenica, Mirjana

(Elsevier Science BV, Amsterdam, 2015)

TY  - JOUR
AU  - Kostić, Nada
AU  - Dotsikas, Yannis
AU  - Jović, Nebojša
AU  - Stevanović, Galina
AU  - Malenović, Anđelija
AU  - Medenica, Mirjana
PY  - 2015
UR  - https://farfar.pharmacy.bg.ac.rs/handle/123456789/2410
AB  - In this paper, novel LC-MS/MS methods for the determination of antiepileptic drug pregabalin in dried matrix spots (DMS) are presented. This attractive technique of sample collection in micro amount was utilized in the form of dried blood spots (DBS) and dried plasma spots (DPS). Following a pre-column derivatization procedure, using n-propyl chloroformate in the presence of n-propanol, and consecutive liquid-liquid extraction, derivatized pregabalin and its internal standard, 4-aminocyclohexanecarboxylic acid, were detected in positive ion mode by applying two SRM transitions per analyte. A YMC-Pack Octyl column (50 mm x 4.0 mm, 3 mu m particle size) maintained at 30 degrees C, was utilized with running mobile phase composed of acetonitrile: 0.15% formic acid (85:15, v/v). Flow rate was 550 mu L/min and total run time 2 min. Established methods were fully validated over the concentration range of 0.200-20.0 mu g/mL for DBS and 0.400-40.0 mu g/mL for DPS, respectively, while specificity, accuracy, precision, recovery, matrix-effect, stability, dilution integrity and spot homogeneity were found within acceptance criteria. Validated methods were applied for the determination of pregabalin levels in dried blood and plasma samples obtained from patients with epilepsy, after per os administration of commercial capsules. Comparison of drug level in blood and plasma, as well as correction steps undertaken in order to overcome hematocrit issue, when analyzing DBS, are also given.
PB  - Elsevier Science BV, Amsterdam
T2  - Journal of Pharmaceutical and Biomedical Analysis
T1  - Quantitation of pregabalin in dried blood spots and dried plasma spots by validated LC-MS/MS methods
VL  - 109
SP  - 79
EP  - 84
DO  - 10.1016/j.jpba.2015.02.023
ER  - 
@article{
author = "Kostić, Nada and Dotsikas, Yannis and Jović, Nebojša and Stevanović, Galina and Malenović, Anđelija and Medenica, Mirjana",
year = "2015",
abstract = "In this paper, novel LC-MS/MS methods for the determination of antiepileptic drug pregabalin in dried matrix spots (DMS) are presented. This attractive technique of sample collection in micro amount was utilized in the form of dried blood spots (DBS) and dried plasma spots (DPS). Following a pre-column derivatization procedure, using n-propyl chloroformate in the presence of n-propanol, and consecutive liquid-liquid extraction, derivatized pregabalin and its internal standard, 4-aminocyclohexanecarboxylic acid, were detected in positive ion mode by applying two SRM transitions per analyte. A YMC-Pack Octyl column (50 mm x 4.0 mm, 3 mu m particle size) maintained at 30 degrees C, was utilized with running mobile phase composed of acetonitrile: 0.15% formic acid (85:15, v/v). Flow rate was 550 mu L/min and total run time 2 min. Established methods were fully validated over the concentration range of 0.200-20.0 mu g/mL for DBS and 0.400-40.0 mu g/mL for DPS, respectively, while specificity, accuracy, precision, recovery, matrix-effect, stability, dilution integrity and spot homogeneity were found within acceptance criteria. Validated methods were applied for the determination of pregabalin levels in dried blood and plasma samples obtained from patients with epilepsy, after per os administration of commercial capsules. Comparison of drug level in blood and plasma, as well as correction steps undertaken in order to overcome hematocrit issue, when analyzing DBS, are also given.",
publisher = "Elsevier Science BV, Amsterdam",
journal = "Journal of Pharmaceutical and Biomedical Analysis",
title = "Quantitation of pregabalin in dried blood spots and dried plasma spots by validated LC-MS/MS methods",
volume = "109",
pages = "79-84",
doi = "10.1016/j.jpba.2015.02.023"
}
Kostić, N., Dotsikas, Y., Jović, N., Stevanović, G., Malenović, A.,& Medenica, M.. (2015). Quantitation of pregabalin in dried blood spots and dried plasma spots by validated LC-MS/MS methods. in Journal of Pharmaceutical and Biomedical Analysis
Elsevier Science BV, Amsterdam., 109, 79-84.
https://doi.org/10.1016/j.jpba.2015.02.023
Kostić N, Dotsikas Y, Jović N, Stevanović G, Malenović A, Medenica M. Quantitation of pregabalin in dried blood spots and dried plasma spots by validated LC-MS/MS methods. in Journal of Pharmaceutical and Biomedical Analysis. 2015;109:79-84.
doi:10.1016/j.jpba.2015.02.023 .
Kostić, Nada, Dotsikas, Yannis, Jović, Nebojša, Stevanović, Galina, Malenović, Anđelija, Medenica, Mirjana, "Quantitation of pregabalin in dried blood spots and dried plasma spots by validated LC-MS/MS methods" in Journal of Pharmaceutical and Biomedical Analysis, 109 (2015):79-84,
https://doi.org/10.1016/j.jpba.2015.02.023 . .
36
31
33

Vigabatrin in dried plasma spots: Validation of a novel LC-MS/MS method and application to clinical practice

Kostić, Nada; Dotsikas, Yannis; Jović, Nebojša; Stevanović, Galina; Malenović, Anđelija; Medenica, Mirjana

(Elsevier Science BV, Amsterdam, 2014)

TY  - JOUR
AU  - Kostić, Nada
AU  - Dotsikas, Yannis
AU  - Jović, Nebojša
AU  - Stevanović, Galina
AU  - Malenović, Anđelija
AU  - Medenica, Mirjana
PY  - 2014
UR  - https://farfar.pharmacy.bg.ac.rs/handle/123456789/2212
AB  - This paper presents a LC-MS/MS method for the determination of antiepileptic drug vigabatrin in dried plasma spots (DPS). Due to its zwitterionic chemical structure, a pre-column derivatization procedure was performed, aiming to yield enhanced ionization efficiency and improved chromatographic behaviour. Propyl chloroformate, in the presence of propanol, was selected as the best derivatization reagent, providing a strong signal along with reasonable run time. A relatively novel sample collection technique, DPS, was utilized, offering easy sample handling and analysis, using a sample in micro amount (similar to 5 mu L). Derivatized vigabatrin and its internal standard, 4-aminocyclohexanecarboxylic acid, were extracted by liquid-liquid extraction (LLE) and determined in positive ion mode by applying two SRM transitions per analyte. A Zorbax Eclipse XDB-C8 column (150 x 4.6 mm, 5 mu m particle size) maintained at 30 degrees C, was utilized with running mobile phase composed of acetonitrile: 0.15% formic acid (85:15, v/v). Flow rate was 550 mu L/min and total run time 4.5 min. The assay exhibited excellent linearity over the concentration range of 0.500-50.0 mu g/mL, which is suitable for the determination of vigabatrin level after per os administration in children and youths with epilepsy, who were on vigabatrin therapy, with or without co-medication. Specificity, accuracy, precision, recovery, matrix-effect and stability were also estimated and assessed within acceptance criteria.
PB  - Elsevier Science BV, Amsterdam
T2  - Journal of Chromatography B-Analytical Technologies in the Biomedical and Life Sciences
T1  - Vigabatrin in dried plasma spots: Validation of a novel LC-MS/MS method and application to clinical practice
VL  - 962
SP  - 102
EP  - 108
DO  - 10.1016/j.jchromb.2014.05.037
ER  - 
@article{
author = "Kostić, Nada and Dotsikas, Yannis and Jović, Nebojša and Stevanović, Galina and Malenović, Anđelija and Medenica, Mirjana",
year = "2014",
abstract = "This paper presents a LC-MS/MS method for the determination of antiepileptic drug vigabatrin in dried plasma spots (DPS). Due to its zwitterionic chemical structure, a pre-column derivatization procedure was performed, aiming to yield enhanced ionization efficiency and improved chromatographic behaviour. Propyl chloroformate, in the presence of propanol, was selected as the best derivatization reagent, providing a strong signal along with reasonable run time. A relatively novel sample collection technique, DPS, was utilized, offering easy sample handling and analysis, using a sample in micro amount (similar to 5 mu L). Derivatized vigabatrin and its internal standard, 4-aminocyclohexanecarboxylic acid, were extracted by liquid-liquid extraction (LLE) and determined in positive ion mode by applying two SRM transitions per analyte. A Zorbax Eclipse XDB-C8 column (150 x 4.6 mm, 5 mu m particle size) maintained at 30 degrees C, was utilized with running mobile phase composed of acetonitrile: 0.15% formic acid (85:15, v/v). Flow rate was 550 mu L/min and total run time 4.5 min. The assay exhibited excellent linearity over the concentration range of 0.500-50.0 mu g/mL, which is suitable for the determination of vigabatrin level after per os administration in children and youths with epilepsy, who were on vigabatrin therapy, with or without co-medication. Specificity, accuracy, precision, recovery, matrix-effect and stability were also estimated and assessed within acceptance criteria.",
publisher = "Elsevier Science BV, Amsterdam",
journal = "Journal of Chromatography B-Analytical Technologies in the Biomedical and Life Sciences",
title = "Vigabatrin in dried plasma spots: Validation of a novel LC-MS/MS method and application to clinical practice",
volume = "962",
pages = "102-108",
doi = "10.1016/j.jchromb.2014.05.037"
}
Kostić, N., Dotsikas, Y., Jović, N., Stevanović, G., Malenović, A.,& Medenica, M.. (2014). Vigabatrin in dried plasma spots: Validation of a novel LC-MS/MS method and application to clinical practice. in Journal of Chromatography B-Analytical Technologies in the Biomedical and Life Sciences
Elsevier Science BV, Amsterdam., 962, 102-108.
https://doi.org/10.1016/j.jchromb.2014.05.037
Kostić N, Dotsikas Y, Jović N, Stevanović G, Malenović A, Medenica M. Vigabatrin in dried plasma spots: Validation of a novel LC-MS/MS method and application to clinical practice. in Journal of Chromatography B-Analytical Technologies in the Biomedical and Life Sciences. 2014;962:102-108.
doi:10.1016/j.jchromb.2014.05.037 .
Kostić, Nada, Dotsikas, Yannis, Jović, Nebojša, Stevanović, Galina, Malenović, Anđelija, Medenica, Mirjana, "Vigabatrin in dried plasma spots: Validation of a novel LC-MS/MS method and application to clinical practice" in Journal of Chromatography B-Analytical Technologies in the Biomedical and Life Sciences, 962 (2014):102-108,
https://doi.org/10.1016/j.jchromb.2014.05.037 . .