Rhee, Kyong Yop

Link to this page

Authority KeyName Variants
cb9b9639-da7a-4f6d-a2fb-359f354cc3f7
  • Rhee, Kyong Yop (1)
Projects

Author's Bibliography

Gentamicin-Loaded Bioactive Hydroxyapatite/Chitosan Composite Coating Electrodeposited on Titanium

Stevanović, Milena; Đosić, Marija; Janković, Ana; Kojić, Vesna; Vukašinović-Sekulić, Maja; Stojanović, Jovica; Odović, Jadranka; Crevar-Sakač, Milkica; Rhee, Kyong Yop; Mišković-Stanković, Vesna

(Amer Chemical Soc, Washington, 2018)

TY  - JOUR
AU  - Stevanović, Milena
AU  - Đosić, Marija
AU  - Janković, Ana
AU  - Kojić, Vesna
AU  - Vukašinović-Sekulić, Maja
AU  - Stojanović, Jovica
AU  - Odović, Jadranka
AU  - Crevar-Sakač, Milkica
AU  - Rhee, Kyong Yop
AU  - Mišković-Stanković, Vesna
PY  - 2018
UR  - https://farfar.pharmacy.bg.ac.rs/handle/123456789/3123
AB  - Composite coating of antibiotic gentamicin (Gent), natural polymer chitosan (CS), and hydroxyapatite (HAP) was successfully assessed by applying the electrophoretic deposition (EPD) technique. EPD was performed under optimized deposition conditions (5 V, 12 min) on pure titanium plates, to obtain HAP/CS and HAP/CS/Gent composite coatings in a single step from three-component aqueous suspension, with favorable antibacterial properties. Composite coatings were characterized by X-ray diffraction (XRD), field emission scanning electron microscopy, Fourier transform infrared spectroscopy, thermogravimetric analysis, and X-ray photoelectron analysis, confirming the formation of composite HAP/CS and HAP/CS/Gent coatings on the titanium surface, which is due to intermolecular hydrogen bonds. Employing the XRD technique, HAP was detected by obtaining the characteristic diffraction maximums. Good antibacterial activity of the composite coating loaded with antibiotic (HAP/CS/Gent) was confirmed against Staphylococcus aureus and Escherichia coli, pointing to the high potential for bioapplication. Introduction of gentamicin in HAP/CS/Gent coating caused very mild cytotoxicity in the tested cell lines MRC-5 and L929. MTT testing was used to evaluate cell viability, and HAP/CS was classified as noncytotoxic.
PB  - Amer Chemical Soc, Washington
T2  - ACS Biomaterials Science & Engineering
T1  - Gentamicin-Loaded Bioactive Hydroxyapatite/Chitosan Composite Coating Electrodeposited on Titanium
VL  - 4
IS  - 12
SP  - 3994
EP  - 4007
DO  - 10.1021/acsbiomaterials.8b00859
ER  - 
@article{
author = "Stevanović, Milena and Đosić, Marija and Janković, Ana and Kojić, Vesna and Vukašinović-Sekulić, Maja and Stojanović, Jovica and Odović, Jadranka and Crevar-Sakač, Milkica and Rhee, Kyong Yop and Mišković-Stanković, Vesna",
year = "2018",
abstract = "Composite coating of antibiotic gentamicin (Gent), natural polymer chitosan (CS), and hydroxyapatite (HAP) was successfully assessed by applying the electrophoretic deposition (EPD) technique. EPD was performed under optimized deposition conditions (5 V, 12 min) on pure titanium plates, to obtain HAP/CS and HAP/CS/Gent composite coatings in a single step from three-component aqueous suspension, with favorable antibacterial properties. Composite coatings were characterized by X-ray diffraction (XRD), field emission scanning electron microscopy, Fourier transform infrared spectroscopy, thermogravimetric analysis, and X-ray photoelectron analysis, confirming the formation of composite HAP/CS and HAP/CS/Gent coatings on the titanium surface, which is due to intermolecular hydrogen bonds. Employing the XRD technique, HAP was detected by obtaining the characteristic diffraction maximums. Good antibacterial activity of the composite coating loaded with antibiotic (HAP/CS/Gent) was confirmed against Staphylococcus aureus and Escherichia coli, pointing to the high potential for bioapplication. Introduction of gentamicin in HAP/CS/Gent coating caused very mild cytotoxicity in the tested cell lines MRC-5 and L929. MTT testing was used to evaluate cell viability, and HAP/CS was classified as noncytotoxic.",
publisher = "Amer Chemical Soc, Washington",
journal = "ACS Biomaterials Science & Engineering",
title = "Gentamicin-Loaded Bioactive Hydroxyapatite/Chitosan Composite Coating Electrodeposited on Titanium",
volume = "4",
number = "12",
pages = "3994-4007",
doi = "10.1021/acsbiomaterials.8b00859"
}
Stevanović, M., Đosić, M., Janković, A., Kojić, V., Vukašinović-Sekulić, M., Stojanović, J., Odović, J., Crevar-Sakač, M., Rhee, K. Y.,& Mišković-Stanković, V.. (2018). Gentamicin-Loaded Bioactive Hydroxyapatite/Chitosan Composite Coating Electrodeposited on Titanium. in ACS Biomaterials Science & Engineering
Amer Chemical Soc, Washington., 4(12), 3994-4007.
https://doi.org/10.1021/acsbiomaterials.8b00859
Stevanović M, Đosić M, Janković A, Kojić V, Vukašinović-Sekulić M, Stojanović J, Odović J, Crevar-Sakač M, Rhee KY, Mišković-Stanković V. Gentamicin-Loaded Bioactive Hydroxyapatite/Chitosan Composite Coating Electrodeposited on Titanium. in ACS Biomaterials Science & Engineering. 2018;4(12):3994-4007.
doi:10.1021/acsbiomaterials.8b00859 .
Stevanović, Milena, Đosić, Marija, Janković, Ana, Kojić, Vesna, Vukašinović-Sekulić, Maja, Stojanović, Jovica, Odović, Jadranka, Crevar-Sakač, Milkica, Rhee, Kyong Yop, Mišković-Stanković, Vesna, "Gentamicin-Loaded Bioactive Hydroxyapatite/Chitosan Composite Coating Electrodeposited on Titanium" in ACS Biomaterials Science & Engineering, 4, no. 12 (2018):3994-4007,
https://doi.org/10.1021/acsbiomaterials.8b00859 . .
58
34
59