Приказ основних података о документу

dc.creatorAleksić, Mara
dc.creatorRadulović, Valentina
dc.creatorLijeskić, Nikola
dc.creatorKapetanović, Vera
dc.date.accessioned2019-09-02T11:29:53Z
dc.date.available2019-09-02T11:29:53Z
dc.date.issued2012
dc.identifier.issn1573-4110
dc.identifier.urihttps://farfar.pharmacy.bg.ac.rs/handle/123456789/1739
dc.description.abstractThe electrochemical study of varenicline (VAR) was done in a wide pH range (2-12), at boron doped diamond electrode (BDDE), glassy carbon electrode (GCE) and hanging mercury electrode (HMDE), using cyclic (CV), square wave (SW) and adsorptive stripping square wave (AdSSW) voltammetric techniques. Depending on the pH and the type of the working electrode the characteristic electrochemical behavior of varenicline was established. The mechanism of the reduction process was suggested. Based on the obtained results, the new electroanalytical method was developed for its determination in the buffer solutions and plasma samples. By applying a square wave voltammetry (SWV) on BDDE and GCE, at pH 3.5 and 4.0, the linear dependence in plasma samples was achieved within the concentration range from 2 10(-6) -1 x 10(-5) M and 4 x 10(-6) -1 x 10(-5) M, respectively. Limit of detection (LOD) and limit of quantification (LOQ) were obtained as 7.1 x 10(-7) M and 2.4 x 10(-6) M on BDDE, and 1.0 x 10(-6) M and 3.5 x 10(-6) M on GCE, respectively. The recovery and RSD values obtained for VAR in plasma suggested BDDE electrode to be preferable in comparison with GCE. The accuracy of the voltammetric method was confirmed by the determination of VAR in plasma spiked with Champix (R) tablets and the results were statistically compared with those obtained with Ultra Performance Liquid Chromatography (UPLC) method, as a reference one.en
dc.publisherBentham Science Publ Ltd, Sharjah
dc.relationinfo:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/172033/RS//
dc.rightsrestrictedAccess
dc.sourceCurrent Analytical Chemistry
dc.subjectBoron doped diamond electrodeen
dc.subjectGlassy carbon electrodeen
dc.subjectHanging mercury drop electrodeen
dc.subjectPlasmaen
dc.subjectReductionen
dc.subjectVareniclineen
dc.titleElectrochemical Response and Determination of Varenicline at Boron Doped Diamond, Glassy Carbon and Hanging Mercury Electrodesen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractКапетановић, Вера; Радуловић, Валентина; Лијескић, Никола; Aлексић, Мара;
dc.citation.volume8
dc.citation.issue1
dc.citation.spage133
dc.citation.epage142
dc.citation.other8(1): 133-142
dc.citation.rankM23
dc.identifier.wos000300391000011
dc.identifier.scopus2-s2.0-84855289194
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_farfar_1739