FarFaR - Farmaceutski fakultet, repozitorijum
Univerzitet u Beogradu, Farmaceutski fakultet
    • English
    • Српски
    • Српски (Serbia)
  • Srpski (latinica) 
    • Engleski
    • Srpski (ćirilica)
    • Srpski (latinica)
  • Prijava
Pregled zapisa 
  •   FarFaR
  • Pharmacy
  • Radovi istraživača / Researchers’ publications
  • Pregled zapisa
  •   FarFaR
  • Pharmacy
  • Radovi istraživača / Researchers’ publications
  • Pregled zapisa
JavaScript is disabled for your browser. Some features of this site may not work without it.

Pulse perturbation technique for determination of piroxicam in pharmaceuticals using an oscillatory reaction system

Thumbnail
2013
1938.pdf (1017.Kb)
Autori
Pejić, Nataša
Sarap, Nataša B.
Maksimović, Jelena
Anić, Slobodan
Kolar-Anić, Ljiljana
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentu
Apstrakt
A simple and reliable novel kinetic method for the determination of piroxicam (PX) was proposed and validated. For quantitative determination of PX, the Bray-Liebhafsky (BL) oscillatory reaction was used in a stable non-equilibrium stationary state close to the bifurcation point. Under the optimized reaction conditions (T = 55.0A degrees C, [H2SO4](0) = 7.60x10(-2) mol L-1, [KIO3](0) = 5.90x10(-2) mol L-1, [H2O2](0) = 1.50x10(-1) mol L-1 and j (0) = 2.95x10(-2) min(-1)), the linear relationship between maximal potential shift Delta E (m) , and PX concentration was obtained in the concentration range 11.2-480.5 A mu g mL(-1) with a detection limit of 9.9 A mu g mL(-1). The method had a rather good sample throughput of 25 samples h(-1) with a precision RSD = 4.7% as well as recoveries RCV a parts per thousand currency sign 104.4%. Applicability of the proposed method to the direct determination of piroxicam in different pharmaceutical formulations (tablets, ampoules and gel) was demonstr...ated.

Ključne reči:
Piroxicam / Perturbation technique / Bray-Liebhafsky oscillatory reaction / Pharmaceutical preparations
Izvor:
Central European Journal of Chemistry, 2013, 11, 2, 180-188
Izdavač:
  • Versita, Warsaw
Finansiranje / projekti:
  • Dinamika nelinearnih fizičkohemijskih i biohemijskih sistema sa modeliranjem i predviđanjem njihovih ponašanja pod neravnotežnim uslovima (RS-172015)

DOI: 10.2478/s11532-012-0146-7

ISSN: 1895-1066

WoS: 000311778700008

Scopus: 2-s2.0-84875741601
[ Google Scholar ]
8
8
URI
https://farfar.pharmacy.bg.ac.rs/handle/123456789/1940
Kolekcije
  • Radovi istraživača / Researchers’ publications
Institucija/grupa
Pharmacy
TY  - JOUR
AU  - Pejić, Nataša
AU  - Sarap, Nataša B.
AU  - Maksimović, Jelena
AU  - Anić, Slobodan
AU  - Kolar-Anić, Ljiljana
PY  - 2013
UR  - https://farfar.pharmacy.bg.ac.rs/handle/123456789/1940
AB  - A simple and reliable novel kinetic method for the determination of piroxicam (PX) was proposed and validated. For quantitative determination of PX, the Bray-Liebhafsky (BL) oscillatory reaction was used in a stable non-equilibrium stationary state close to the bifurcation point. Under the optimized reaction conditions (T = 55.0A degrees C, [H2SO4](0) = 7.60x10(-2) mol L-1, [KIO3](0) = 5.90x10(-2) mol L-1, [H2O2](0) = 1.50x10(-1) mol L-1 and j (0) = 2.95x10(-2) min(-1)), the linear relationship between maximal potential shift Delta E (m) , and PX concentration was obtained in the concentration range 11.2-480.5 A mu g mL(-1) with a detection limit of 9.9 A mu g mL(-1). The method had a rather good sample throughput of 25 samples h(-1) with a precision RSD = 4.7% as well as recoveries RCV a parts per thousand currency sign 104.4%. Applicability of the proposed method to the direct determination of piroxicam in different pharmaceutical formulations (tablets, ampoules and gel) was demonstrated.
PB  - Versita, Warsaw
T2  - Central European Journal of Chemistry
T1  - Pulse perturbation technique for determination of piroxicam in pharmaceuticals using an oscillatory reaction system
VL  - 11
IS  - 2
SP  - 180
EP  - 188
DO  - 10.2478/s11532-012-0146-7
ER  - 
@article{
author = "Pejić, Nataša and Sarap, Nataša B. and Maksimović, Jelena and Anić, Slobodan and Kolar-Anić, Ljiljana",
year = "2013",
abstract = "A simple and reliable novel kinetic method for the determination of piroxicam (PX) was proposed and validated. For quantitative determination of PX, the Bray-Liebhafsky (BL) oscillatory reaction was used in a stable non-equilibrium stationary state close to the bifurcation point. Under the optimized reaction conditions (T = 55.0A degrees C, [H2SO4](0) = 7.60x10(-2) mol L-1, [KIO3](0) = 5.90x10(-2) mol L-1, [H2O2](0) = 1.50x10(-1) mol L-1 and j (0) = 2.95x10(-2) min(-1)), the linear relationship between maximal potential shift Delta E (m) , and PX concentration was obtained in the concentration range 11.2-480.5 A mu g mL(-1) with a detection limit of 9.9 A mu g mL(-1). The method had a rather good sample throughput of 25 samples h(-1) with a precision RSD = 4.7% as well as recoveries RCV a parts per thousand currency sign 104.4%. Applicability of the proposed method to the direct determination of piroxicam in different pharmaceutical formulations (tablets, ampoules and gel) was demonstrated.",
publisher = "Versita, Warsaw",
journal = "Central European Journal of Chemistry",
title = "Pulse perturbation technique for determination of piroxicam in pharmaceuticals using an oscillatory reaction system",
volume = "11",
number = "2",
pages = "180-188",
doi = "10.2478/s11532-012-0146-7"
}
Pejić, N., Sarap, N. B., Maksimović, J., Anić, S.,& Kolar-Anić, L.. (2013). Pulse perturbation technique for determination of piroxicam in pharmaceuticals using an oscillatory reaction system. in Central European Journal of Chemistry
Versita, Warsaw., 11(2), 180-188.
https://doi.org/10.2478/s11532-012-0146-7
Pejić N, Sarap NB, Maksimović J, Anić S, Kolar-Anić L. Pulse perturbation technique for determination of piroxicam in pharmaceuticals using an oscillatory reaction system. in Central European Journal of Chemistry. 2013;11(2):180-188.
doi:10.2478/s11532-012-0146-7 .
Pejić, Nataša, Sarap, Nataša B., Maksimović, Jelena, Anić, Slobodan, Kolar-Anić, Ljiljana, "Pulse perturbation technique for determination of piroxicam in pharmaceuticals using an oscillatory reaction system" in Central European Journal of Chemistry, 11, no. 2 (2013):180-188,
https://doi.org/10.2478/s11532-012-0146-7 . .

DSpace software copyright © 2002-2015  DuraSpace