Приказ основних података о документу

dc.creatorColović, Jelena
dc.creatorVemić, Ana
dc.creatorKostić, Nada
dc.creatorMalenović, Anđelija
dc.creatorMedenica, Mirjana
dc.date.accessioned2019-09-02T11:38:49Z
dc.date.available2019-09-02T11:38:49Z
dc.date.issued2014
dc.identifier.issn1615-9306
dc.identifier.urihttps://farfar.pharmacy.bg.ac.rs/handle/123456789/2092
dc.description.abstractIn this paper, the capability of a polynomial-modified Gaussian model to relate the peak shape of basic analytes, amlodipine, and its impurity A, with the change of chromatographic conditions was tested. For the accurate simulation of real chromatographic peaks the authors proposed the three-step procedure based on indirect modeling of peak width at 10% of peak height (W-0.1), individual values of left-half width (A) and right-half width (B), number of theoretical plates (N), and tailing factor (Tf). The values of retention factors corresponding to the peak beginning (k(B)), peak apex (k(A)), peak ending (k(E)), and peak heights (H-0) of the analytes were directly modeled. Then, the investigated experimental domain was divided to acquire a grid of appropriate density, which allowed the subsequent calculation of W-0.1, A, B, N, and Tf. On the basis of the predicted results for Tf and N, as well as the defined criteria for the simulation the following conditions were selected: 33% acetonitrile/67% aqueous phase (55 mM perchloric acid, pH 2.2) at 40 degrees C column temperature. Perfect agreement between predicted and experimental values was obtained confirming the ability of polynomial modified Gaussian model and three-step procedure to successfully simulate the real chromatograms in ion-interaction chromatography.en
dc.publisherWiley-VCH Verlag GMBH, Weinheim
dc.relationinfo:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/172052/RS//
dc.rightsrestrictedAccess
dc.sourceJournal of Separation Science
dc.subjectIndirect modelingen
dc.subjectIon-interaction chromatographyen
dc.subjectModified Gaussian modelen
dc.subjectPeak shape simulationen
dc.titleTesting the capability of a polynomial-modified gaussian model in the description and simulation of chromatographic peaks of amlodipine and its impurity in ion-interaction chromatographyen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractЦоловић, Јелена; Костић, Нада; Вемић, Aна; Маленовић, Aнђелија; Меденица, Мирјана;
dc.citation.volume37
dc.citation.issue14
dc.citation.spage1797
dc.citation.epage1804
dc.citation.other37(14): 1797-1804
dc.citation.rankM21
dc.identifier.wos000339669700011
dc.identifier.doi10.1002/jssc.201400206
dc.identifier.pmid24798430
dc.identifier.scopus2-s2.0-84904471836