Determination of metal traces in wine by argon stabilized d.c. arc
Само за регистроване кориснике
1999
Чланак у часопису (Објављена верзија)

Метаподаци
Приказ свих података о документуАпстракт
A spetroscopic method for the determination of metal traces (Mn, Cu, Fe) in wine has been developed based on argon stabilized d.c. are plasma at atmospheric pressure. The experimental conditions were optimized using lateral distributions of spectral line intensities of the trace elements in aqueous and ethanol-aqueous solutions. The method was applied to the analysis of 6 wines from 3 Serbian wine-growing regions. Direct and standard addition methods were tested. The precision of the method is characterized by a relative standard deviation of 0.50-3.00%. The accuracy of the method was assessed by flame AAS.
Извор:
Fresenius' Journal of Analytical Chemistry, 1999, 365, 4, 367-370Издавач:
- Springer Verlag, New York
DOI: 10.1007/s002160051502
ISSN: 0937-0633
WoS: 000083325800013
Scopus: 2-s2.0-2542540941
Институција/група
PharmacyTY - JOUR AU - Ražić, Slavica AU - Todorovic, M AU - Holclajtner-Antunović, Ivanka AU - Stoiljkovic, M PY - 1999 UR - https://farfar.pharmacy.bg.ac.rs/handle/123456789/216 AB - A spetroscopic method for the determination of metal traces (Mn, Cu, Fe) in wine has been developed based on argon stabilized d.c. are plasma at atmospheric pressure. The experimental conditions were optimized using lateral distributions of spectral line intensities of the trace elements in aqueous and ethanol-aqueous solutions. The method was applied to the analysis of 6 wines from 3 Serbian wine-growing regions. Direct and standard addition methods were tested. The precision of the method is characterized by a relative standard deviation of 0.50-3.00%. The accuracy of the method was assessed by flame AAS. PB - Springer Verlag, New York T2 - Fresenius' Journal of Analytical Chemistry T1 - Determination of metal traces in wine by argon stabilized d.c. arc VL - 365 IS - 4 SP - 367 EP - 370 DO - 10.1007/s002160051502 ER -
@article{ author = "Ražić, Slavica and Todorovic, M and Holclajtner-Antunović, Ivanka and Stoiljkovic, M", year = "1999", abstract = "A spetroscopic method for the determination of metal traces (Mn, Cu, Fe) in wine has been developed based on argon stabilized d.c. are plasma at atmospheric pressure. The experimental conditions were optimized using lateral distributions of spectral line intensities of the trace elements in aqueous and ethanol-aqueous solutions. The method was applied to the analysis of 6 wines from 3 Serbian wine-growing regions. Direct and standard addition methods were tested. The precision of the method is characterized by a relative standard deviation of 0.50-3.00%. The accuracy of the method was assessed by flame AAS.", publisher = "Springer Verlag, New York", journal = "Fresenius' Journal of Analytical Chemistry", title = "Determination of metal traces in wine by argon stabilized d.c. arc", volume = "365", number = "4", pages = "367-370", doi = "10.1007/s002160051502" }
Ražić, S., Todorovic, M., Holclajtner-Antunović, I.,& Stoiljkovic, M.. (1999). Determination of metal traces in wine by argon stabilized d.c. arc. in Fresenius' Journal of Analytical Chemistry Springer Verlag, New York., 365(4), 367-370. https://doi.org/10.1007/s002160051502
Ražić S, Todorovic M, Holclajtner-Antunović I, Stoiljkovic M. Determination of metal traces in wine by argon stabilized d.c. arc. in Fresenius' Journal of Analytical Chemistry. 1999;365(4):367-370. doi:10.1007/s002160051502 .
Ražić, Slavica, Todorovic, M, Holclajtner-Antunović, Ivanka, Stoiljkovic, M, "Determination of metal traces in wine by argon stabilized d.c. arc" in Fresenius' Journal of Analytical Chemistry, 365, no. 4 (1999):367-370, https://doi.org/10.1007/s002160051502 . .