Desirability Based Optimization and Validation of New RP-HPLC Method for Simultaneous Determination of Bisoprolol Fumarate, Hydrochlorothiazide and Their Impurities
Authorized Users Only
2016
Authors
Dobričić, VladimirVulović-Tadić, Miljana
Jančić-Stojanović, Biljana
Vladimirov, Sote
Čudina, Olivera
Article (Published version)
Metadata
Show full item recordAbstract
In this paper optimization and validation of a new RP-HPLC method for simultaneous determination of bisoprolol fumarate, hydrochlorothiazide and impurities A, L, K and B are presented. Factors which could have significant influence on separation were selected: percentage of mobile phase B [acetonitrile-ammonium dihydrogen phosphate/orthophosphoric acid buffer solution (80:20, v/v)] at defined t (1) and t (2) of the gradient, ammonium dihydrogen phosphate concentration and pH value of the buffer solution (mobile phase A). Selected factors were varied according to Box-Behnken plan of experiments and their influence on critical pairs separation was investigated. DerringerA ' s desirability function was used for selection of optimal chromatographic conditions. Finally, optimal values of investigated factors were 34.4 % (t (1)) and 38.0 % (t (2)) of mobile phase B, 46.5 mM ammonium dihydrogen phosphate concentration and pH 3.35. The method was successfully validated according to ICH guideli...nes acceptance criteria for robustness, selectivity, linearity, accuracy and precision. Small variations of selected chromatographic parameters did not affect qualitative and quantitative system responses significantly, which proved the method's robustness. Limits of quantification (LOQ) and detection (LOD) for impurities were determined and LOQ values were the first points in linearity testing. Linearity was confirmed by r a parts per thousand yen 0.9945 (impurities) and r = 0.9998 (active substances). Accuracy was confirmed by calculated recoveries [93.5-107.1 % (impurities) and 98.1-101.9 % (active substances)]. Precision was tested at three levels: injection repeatability, analysis repeatability and intermediate precision. Calculated relative standard deviations were less than 1, 2 and 3 %, respectively. Finally, the method was applied to real sample analysis.
Source:
Chromatographia, 2016, 79, 9-10, 571-579Publisher:
- Springer Heidelberg, Heidelberg
Funding / projects:
- Development of molecules with antiinflammatory and cardioprotective activity: structural modifications, modelling, physicochemical characterization and formulation investigations (RS-MESTD-Basic Research (BR or ON)-172041)
DOI: 10.1007/s10337-016-3065-5
ISSN: 0009-5893
WoS: 000376125000005
Scopus: 2-s2.0-84960447227
Collections
Institution/Community
PharmacyTY - JOUR AU - Dobričić, Vladimir AU - Vulović-Tadić, Miljana AU - Jančić-Stojanović, Biljana AU - Vladimirov, Sote AU - Čudina, Olivera PY - 2016 UR - https://farfar.pharmacy.bg.ac.rs/handle/123456789/2555 AB - In this paper optimization and validation of a new RP-HPLC method for simultaneous determination of bisoprolol fumarate, hydrochlorothiazide and impurities A, L, K and B are presented. Factors which could have significant influence on separation were selected: percentage of mobile phase B [acetonitrile-ammonium dihydrogen phosphate/orthophosphoric acid buffer solution (80:20, v/v)] at defined t (1) and t (2) of the gradient, ammonium dihydrogen phosphate concentration and pH value of the buffer solution (mobile phase A). Selected factors were varied according to Box-Behnken plan of experiments and their influence on critical pairs separation was investigated. DerringerA ' s desirability function was used for selection of optimal chromatographic conditions. Finally, optimal values of investigated factors were 34.4 % (t (1)) and 38.0 % (t (2)) of mobile phase B, 46.5 mM ammonium dihydrogen phosphate concentration and pH 3.35. The method was successfully validated according to ICH guidelines acceptance criteria for robustness, selectivity, linearity, accuracy and precision. Small variations of selected chromatographic parameters did not affect qualitative and quantitative system responses significantly, which proved the method's robustness. Limits of quantification (LOQ) and detection (LOD) for impurities were determined and LOQ values were the first points in linearity testing. Linearity was confirmed by r a parts per thousand yen 0.9945 (impurities) and r = 0.9998 (active substances). Accuracy was confirmed by calculated recoveries [93.5-107.1 % (impurities) and 98.1-101.9 % (active substances)]. Precision was tested at three levels: injection repeatability, analysis repeatability and intermediate precision. Calculated relative standard deviations were less than 1, 2 and 3 %, respectively. Finally, the method was applied to real sample analysis. PB - Springer Heidelberg, Heidelberg T2 - Chromatographia T1 - Desirability Based Optimization and Validation of New RP-HPLC Method for Simultaneous Determination of Bisoprolol Fumarate, Hydrochlorothiazide and Their Impurities VL - 79 IS - 9-10 SP - 571 EP - 579 DO - 10.1007/s10337-016-3065-5 ER -
@article{ author = "Dobričić, Vladimir and Vulović-Tadić, Miljana and Jančić-Stojanović, Biljana and Vladimirov, Sote and Čudina, Olivera", year = "2016", abstract = "In this paper optimization and validation of a new RP-HPLC method for simultaneous determination of bisoprolol fumarate, hydrochlorothiazide and impurities A, L, K and B are presented. Factors which could have significant influence on separation were selected: percentage of mobile phase B [acetonitrile-ammonium dihydrogen phosphate/orthophosphoric acid buffer solution (80:20, v/v)] at defined t (1) and t (2) of the gradient, ammonium dihydrogen phosphate concentration and pH value of the buffer solution (mobile phase A). Selected factors were varied according to Box-Behnken plan of experiments and their influence on critical pairs separation was investigated. DerringerA ' s desirability function was used for selection of optimal chromatographic conditions. Finally, optimal values of investigated factors were 34.4 % (t (1)) and 38.0 % (t (2)) of mobile phase B, 46.5 mM ammonium dihydrogen phosphate concentration and pH 3.35. The method was successfully validated according to ICH guidelines acceptance criteria for robustness, selectivity, linearity, accuracy and precision. Small variations of selected chromatographic parameters did not affect qualitative and quantitative system responses significantly, which proved the method's robustness. Limits of quantification (LOQ) and detection (LOD) for impurities were determined and LOQ values were the first points in linearity testing. Linearity was confirmed by r a parts per thousand yen 0.9945 (impurities) and r = 0.9998 (active substances). Accuracy was confirmed by calculated recoveries [93.5-107.1 % (impurities) and 98.1-101.9 % (active substances)]. Precision was tested at three levels: injection repeatability, analysis repeatability and intermediate precision. Calculated relative standard deviations were less than 1, 2 and 3 %, respectively. Finally, the method was applied to real sample analysis.", publisher = "Springer Heidelberg, Heidelberg", journal = "Chromatographia", title = "Desirability Based Optimization and Validation of New RP-HPLC Method for Simultaneous Determination of Bisoprolol Fumarate, Hydrochlorothiazide and Their Impurities", volume = "79", number = "9-10", pages = "571-579", doi = "10.1007/s10337-016-3065-5" }
Dobričić, V., Vulović-Tadić, M., Jančić-Stojanović, B., Vladimirov, S.,& Čudina, O.. (2016). Desirability Based Optimization and Validation of New RP-HPLC Method for Simultaneous Determination of Bisoprolol Fumarate, Hydrochlorothiazide and Their Impurities. in Chromatographia Springer Heidelberg, Heidelberg., 79(9-10), 571-579. https://doi.org/10.1007/s10337-016-3065-5
Dobričić V, Vulović-Tadić M, Jančić-Stojanović B, Vladimirov S, Čudina O. Desirability Based Optimization and Validation of New RP-HPLC Method for Simultaneous Determination of Bisoprolol Fumarate, Hydrochlorothiazide and Their Impurities. in Chromatographia. 2016;79(9-10):571-579. doi:10.1007/s10337-016-3065-5 .
Dobričić, Vladimir, Vulović-Tadić, Miljana, Jančić-Stojanović, Biljana, Vladimirov, Sote, Čudina, Olivera, "Desirability Based Optimization and Validation of New RP-HPLC Method for Simultaneous Determination of Bisoprolol Fumarate, Hydrochlorothiazide and Their Impurities" in Chromatographia, 79, no. 9-10 (2016):571-579, https://doi.org/10.1007/s10337-016-3065-5 . .