Aim: The objective of the study was development of hydrophilic interaction liquid chromatography-ESI/MS/MS method for the determination of olopatadine in tear matrix. Materials & methods: Separation was performed on Acquity BEH amide column (2.1 x 100 mm, 1.7 mu m). The mobile phase was consisted of 0.1% formic acid in water and acetonitrile. Mianserin hydrochloride was implemented as an internal standard. The artificial tear fluid was used as matrix. The tear samples were collected using Schirmer test strips. For the optimization of ultra pressure liquid chromatography conditions, Box-Benhken design was utilized. Results: The optimal values of the ion source and collision cell parameters were found. Quantification was performed in multiple reaction monitoring mode. The optimized method was fully validated. Conclusion: The proposed method was utilized for monitoring of olopatadine in human tear.
Keywords:
Box-Benhken design / human tears / hydrophilic interaction liquid chromatography / olopatadine / UPLC-MS/MSSource:
Bioanalysis, 2017, 9, 24, 1943-1954Publisher:
- Future Sci Ltd, London
Funding / projects:
- Modelling of different chromatographic systems with chemometrical approach in pharmaceutical analysis (RS-172052)
DOI: 10.4155/bio-2017-0172
ISSN: 1757-6180
PubMed: 29205055
WoS: 000417836300003
Scopus: 2-s2.0-85038389914
Collections
Institution/Community
PharmacyTY - JOUR AU - Maksić, Jelena AU - Stajić, Ana AU - Knežević, Miroslav AU - Dacić-Krnjaja, Bojana AU - Jančić-Stojanović, Biljana AU - Medenica, Mirjana PY - 2017 UR - https://farfar.pharmacy.bg.ac.rs/handle/123456789/2860 AB - Aim: The objective of the study was development of hydrophilic interaction liquid chromatography-ESI/MS/MS method for the determination of olopatadine in tear matrix. Materials & methods: Separation was performed on Acquity BEH amide column (2.1 x 100 mm, 1.7 mu m). The mobile phase was consisted of 0.1% formic acid in water and acetonitrile. Mianserin hydrochloride was implemented as an internal standard. The artificial tear fluid was used as matrix. The tear samples were collected using Schirmer test strips. For the optimization of ultra pressure liquid chromatography conditions, Box-Benhken design was utilized. Results: The optimal values of the ion source and collision cell parameters were found. Quantification was performed in multiple reaction monitoring mode. The optimized method was fully validated. Conclusion: The proposed method was utilized for monitoring of olopatadine in human tear. PB - Future Sci Ltd, London T2 - Bioanalysis T1 - Determination of olopatadine in human tears by hydrophilic interaction liquid chromatography-MS/MS method VL - 9 IS - 24 SP - 1943 EP - 1954 DO - 10.4155/bio-2017-0172 ER -
@article{ author = "Maksić, Jelena and Stajić, Ana and Knežević, Miroslav and Dacić-Krnjaja, Bojana and Jančić-Stojanović, Biljana and Medenica, Mirjana", year = "2017", abstract = "Aim: The objective of the study was development of hydrophilic interaction liquid chromatography-ESI/MS/MS method for the determination of olopatadine in tear matrix. Materials & methods: Separation was performed on Acquity BEH amide column (2.1 x 100 mm, 1.7 mu m). The mobile phase was consisted of 0.1% formic acid in water and acetonitrile. Mianserin hydrochloride was implemented as an internal standard. The artificial tear fluid was used as matrix. The tear samples were collected using Schirmer test strips. For the optimization of ultra pressure liquid chromatography conditions, Box-Benhken design was utilized. Results: The optimal values of the ion source and collision cell parameters were found. Quantification was performed in multiple reaction monitoring mode. The optimized method was fully validated. Conclusion: The proposed method was utilized for monitoring of olopatadine in human tear.", publisher = "Future Sci Ltd, London", journal = "Bioanalysis", title = "Determination of olopatadine in human tears by hydrophilic interaction liquid chromatography-MS/MS method", volume = "9", number = "24", pages = "1943-1954", doi = "10.4155/bio-2017-0172" }
Maksić, J., Stajić, A., Knežević, M., Dacić-Krnjaja, B., Jančić-Stojanović, B.,& Medenica, M.. (2017). Determination of olopatadine in human tears by hydrophilic interaction liquid chromatography-MS/MS method. in Bioanalysis Future Sci Ltd, London., 9(24), 1943-1954. https://doi.org/10.4155/bio-2017-0172
Maksić J, Stajić A, Knežević M, Dacić-Krnjaja B, Jančić-Stojanović B, Medenica M. Determination of olopatadine in human tears by hydrophilic interaction liquid chromatography-MS/MS method. in Bioanalysis. 2017;9(24):1943-1954. doi:10.4155/bio-2017-0172 .
Maksić, Jelena, Stajić, Ana, Knežević, Miroslav, Dacić-Krnjaja, Bojana, Jančić-Stojanović, Biljana, Medenica, Mirjana, "Determination of olopatadine in human tears by hydrophilic interaction liquid chromatography-MS/MS method" in Bioanalysis, 9, no. 24 (2017):1943-1954, https://doi.org/10.4155/bio-2017-0172 . .