Highly Sensitive UHPLC-MS/MS Method for Quantification of Ethylenediamine-N,N '-di-2-(3-cyclohexyl) Propanoic Acid Derivatives in Mouse Serum

2017
Autori
Tubić, BiljanaMarković, Bojan

Vladimirov, Sandra

Ristić, Slavica M.
Ivković, Branka

Savić, Miroslav

Poljarević, Jelena
Sabo, Tibor

Članak u časopisu (Objavljena verzija)

Metapodaci
Prikaz svih podataka o dokumentuApstrakt
A series of new (S,S)-ethylenediamine-N,N'-di-2-(3-cyclohexyl)propanoate esters has shown cytotoxic activity towards human leukemic cell lines. The aim of this study was to develop and validate a bioanalytical method for quantification of (S,S)-O,O-diethyl-ethylenediamine-N,N'-di-2-(3-cyclohexyl)propanoate dihydrochlorides (DE-EDCP) and its metabolite, substituted propanoic acid (EDCP), in mouse serum by ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Structural analog, derivative of 1,3-propanediamine, was used as an internal standard (IS). Sample preparation employed protein precipitation by acetonitrile and subsequent centrifugation. Optimal UHPLC separation conditions were set to achieve simultaneous determination of both compounds in a short run time of 6 min. Additionally, the selected reaction monitoring (SRM) mode developed in this method allowed a highly sensitive, accurate, and precise identification of compounds of interest. The lower lim...it of quantitation (LOQ) was 1.3 ng mL(-1) for DE-EDCP and 0.3 mu g mL(-1) for EDCP. The calibration curves were linear over the concentration range of 1.3-26.7 ng mL(-1) and 0.3-6.7 mu g mL(-1) for DE-EDCP and EDCP, respectively. Precision (%CV) and accuracy (% RE) for DE-EDCP and EDCP ranged from 3.5% to 16.0% and from 1.8% to 14.4%, respectively. The validation process was performed in accordance with the regulatory guidance/guideline, and all of the obtained results met the established acceptance criteria. The newly developed and validated UHPLC-MS/MS method is rapid, sensitive, and selective, and it can be successfully applied to drug monitoring in nonclinical studies.
Izvor:
Acta Chromatographica, 2017, 29, 2, 235-252Izdavač:
- Akademiai Kiado Rt, Budapest
Finansiranje / projekti:
DOI: 10.1556/1326.2017.29.2.7
ISSN: 1233-2356
WoS: 000401612800007
Scopus: 2-s2.0-85020063021
Institucija/grupa
PharmacyTY - JOUR AU - Tubić, Biljana AU - Marković, Bojan AU - Vladimirov, Sandra AU - Ristić, Slavica M. AU - Ivković, Branka AU - Savić, Miroslav AU - Poljarević, Jelena AU - Sabo, Tibor PY - 2017 UR - https://farfar.pharmacy.bg.ac.rs/handle/123456789/3024 AB - A series of new (S,S)-ethylenediamine-N,N'-di-2-(3-cyclohexyl)propanoate esters has shown cytotoxic activity towards human leukemic cell lines. The aim of this study was to develop and validate a bioanalytical method for quantification of (S,S)-O,O-diethyl-ethylenediamine-N,N'-di-2-(3-cyclohexyl)propanoate dihydrochlorides (DE-EDCP) and its metabolite, substituted propanoic acid (EDCP), in mouse serum by ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Structural analog, derivative of 1,3-propanediamine, was used as an internal standard (IS). Sample preparation employed protein precipitation by acetonitrile and subsequent centrifugation. Optimal UHPLC separation conditions were set to achieve simultaneous determination of both compounds in a short run time of 6 min. Additionally, the selected reaction monitoring (SRM) mode developed in this method allowed a highly sensitive, accurate, and precise identification of compounds of interest. The lower limit of quantitation (LOQ) was 1.3 ng mL(-1) for DE-EDCP and 0.3 mu g mL(-1) for EDCP. The calibration curves were linear over the concentration range of 1.3-26.7 ng mL(-1) and 0.3-6.7 mu g mL(-1) for DE-EDCP and EDCP, respectively. Precision (%CV) and accuracy (% RE) for DE-EDCP and EDCP ranged from 3.5% to 16.0% and from 1.8% to 14.4%, respectively. The validation process was performed in accordance with the regulatory guidance/guideline, and all of the obtained results met the established acceptance criteria. The newly developed and validated UHPLC-MS/MS method is rapid, sensitive, and selective, and it can be successfully applied to drug monitoring in nonclinical studies. PB - Akademiai Kiado Rt, Budapest T2 - Acta Chromatographica T1 - Highly Sensitive UHPLC-MS/MS Method for Quantification of Ethylenediamine-N,N '-di-2-(3-cyclohexyl) Propanoic Acid Derivatives in Mouse Serum VL - 29 IS - 2 SP - 235 EP - 252 DO - 10.1556/1326.2017.29.2.7 ER -
@article{ author = "Tubić, Biljana and Marković, Bojan and Vladimirov, Sandra and Ristić, Slavica M. and Ivković, Branka and Savić, Miroslav and Poljarević, Jelena and Sabo, Tibor", year = "2017", abstract = "A series of new (S,S)-ethylenediamine-N,N'-di-2-(3-cyclohexyl)propanoate esters has shown cytotoxic activity towards human leukemic cell lines. The aim of this study was to develop and validate a bioanalytical method for quantification of (S,S)-O,O-diethyl-ethylenediamine-N,N'-di-2-(3-cyclohexyl)propanoate dihydrochlorides (DE-EDCP) and its metabolite, substituted propanoic acid (EDCP), in mouse serum by ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Structural analog, derivative of 1,3-propanediamine, was used as an internal standard (IS). Sample preparation employed protein precipitation by acetonitrile and subsequent centrifugation. Optimal UHPLC separation conditions were set to achieve simultaneous determination of both compounds in a short run time of 6 min. Additionally, the selected reaction monitoring (SRM) mode developed in this method allowed a highly sensitive, accurate, and precise identification of compounds of interest. The lower limit of quantitation (LOQ) was 1.3 ng mL(-1) for DE-EDCP and 0.3 mu g mL(-1) for EDCP. The calibration curves were linear over the concentration range of 1.3-26.7 ng mL(-1) and 0.3-6.7 mu g mL(-1) for DE-EDCP and EDCP, respectively. Precision (%CV) and accuracy (% RE) for DE-EDCP and EDCP ranged from 3.5% to 16.0% and from 1.8% to 14.4%, respectively. The validation process was performed in accordance with the regulatory guidance/guideline, and all of the obtained results met the established acceptance criteria. The newly developed and validated UHPLC-MS/MS method is rapid, sensitive, and selective, and it can be successfully applied to drug monitoring in nonclinical studies.", publisher = "Akademiai Kiado Rt, Budapest", journal = "Acta Chromatographica", title = "Highly Sensitive UHPLC-MS/MS Method for Quantification of Ethylenediamine-N,N '-di-2-(3-cyclohexyl) Propanoic Acid Derivatives in Mouse Serum", volume = "29", number = "2", pages = "235-252", doi = "10.1556/1326.2017.29.2.7" }
Tubić, B., Marković, B., Vladimirov, S., Ristić, S. M., Ivković, B., Savić, M., Poljarević, J.,& Sabo, T.. (2017). Highly Sensitive UHPLC-MS/MS Method for Quantification of Ethylenediamine-N,N '-di-2-(3-cyclohexyl) Propanoic Acid Derivatives in Mouse Serum. in Acta Chromatographica Akademiai Kiado Rt, Budapest., 29(2), 235-252. https://doi.org/10.1556/1326.2017.29.2.7
Tubić B, Marković B, Vladimirov S, Ristić SM, Ivković B, Savić M, Poljarević J, Sabo T. Highly Sensitive UHPLC-MS/MS Method for Quantification of Ethylenediamine-N,N '-di-2-(3-cyclohexyl) Propanoic Acid Derivatives in Mouse Serum. in Acta Chromatographica. 2017;29(2):235-252. doi:10.1556/1326.2017.29.2.7 .
Tubić, Biljana, Marković, Bojan, Vladimirov, Sandra, Ristić, Slavica M., Ivković, Branka, Savić, Miroslav, Poljarević, Jelena, Sabo, Tibor, "Highly Sensitive UHPLC-MS/MS Method for Quantification of Ethylenediamine-N,N '-di-2-(3-cyclohexyl) Propanoic Acid Derivatives in Mouse Serum" in Acta Chromatographica, 29, no. 2 (2017):235-252, https://doi.org/10.1556/1326.2017.29.2.7 . .