An approach for determining allowable between reagent lot variation
Authorized Users Only
2022
Authors
Van Schrojenstein Lantman, Marith
Çubukçu, Hikmet Can

Boursier, Guilaine
Panteghini, Mauro
Bernabeu-Andreu, Francisco
Milinković, Neda

Mesko Brguljan, Pika
Linko, Solveig
Brugnoni, Duilio

O'Kelly, Ruth
Kroupis, Christos
Lohmander, Maria
Šprongl, Luděk
Vanstapel, Florent
Thelen, Marc
Article (Published version)

Metadata
Show full item recordAbstract
Clinicians trust medical laboratories to provide reliable results on which they rely for clinical decisions. Lab- oratories fulfil their responsibility for accurate and consistent results by utilizing an arsenal of approaches, ranging from validation and verification experiments to daily quality control procedures. All these procedures verify, on different moments, that the results of a certain examination procedure have analytical performance characteristics (APC) that meet analytical performance specifications (APS) set for a particular intended use. The APC can in part be determined by esti- mating the measurement uncertainty component under con- ditions of within-laboratory precision (uRw), which comprises all components influencing the measurement uncertainty of random sources. To maintain the adequacy of their mea- surement procedures, laboratories need to distinguish aspects that are manageable vs. those that are not. One of the aspects that may influence uRw is the momentary si...gnificant bias caused by shifts in reagent and/or calibrator lots, which, when accepted or unnoticed, become a factor of the APC. In this paper, we postulate a model for allocating a part of allowable uRw to between-reagent lot variation, based on the need for long-term consistency of the measurement variability for that specific measurand. The allocation manages the ratio between short-term and long-term variation and indicates laboratories when to reject or correct certain variations due to reagent lots.
Keywords:
Measurement procedures / measurement uncertainty / position paper / reagent-lotSource:
Clinical Chemistry and Laboratory Medicine, 2022, 60, 5, 681-688Publisher:
- De Gruyter Open Ltd
DOI: 10.1515/cclm-2022-0083
ISSN: 1434-6621
WoS: 000755947900001
Scopus: 2-s2.0-85126043737
Collections
Institution/Community
PharmacyTY - JOUR AU - Van Schrojenstein Lantman, Marith AU - Çubukçu, Hikmet Can AU - Boursier, Guilaine AU - Panteghini, Mauro AU - Bernabeu-Andreu, Francisco AU - Milinković, Neda AU - Mesko Brguljan, Pika AU - Linko, Solveig AU - Brugnoni, Duilio AU - O'Kelly, Ruth AU - Kroupis, Christos AU - Lohmander, Maria AU - Šprongl, Luděk AU - Vanstapel, Florent AU - Thelen, Marc PY - 2022 UR - https://farfar.pharmacy.bg.ac.rs/handle/123456789/4072 AB - Clinicians trust medical laboratories to provide reliable results on which they rely for clinical decisions. Lab- oratories fulfil their responsibility for accurate and consistent results by utilizing an arsenal of approaches, ranging from validation and verification experiments to daily quality control procedures. All these procedures verify, on different moments, that the results of a certain examination procedure have analytical performance characteristics (APC) that meet analytical performance specifications (APS) set for a particular intended use. The APC can in part be determined by esti- mating the measurement uncertainty component under con- ditions of within-laboratory precision (uRw), which comprises all components influencing the measurement uncertainty of random sources. To maintain the adequacy of their mea- surement procedures, laboratories need to distinguish aspects that are manageable vs. those that are not. One of the aspects that may influence uRw is the momentary significant bias caused by shifts in reagent and/or calibrator lots, which, when accepted or unnoticed, become a factor of the APC. In this paper, we postulate a model for allocating a part of allowable uRw to between-reagent lot variation, based on the need for long-term consistency of the measurement variability for that specific measurand. The allocation manages the ratio between short-term and long-term variation and indicates laboratories when to reject or correct certain variations due to reagent lots. PB - De Gruyter Open Ltd T2 - Clinical Chemistry and Laboratory Medicine T1 - An approach for determining allowable between reagent lot variation VL - 60 IS - 5 SP - 681 EP - 688 DO - 10.1515/cclm-2022-0083 ER -
@article{ author = "Van Schrojenstein Lantman, Marith and Çubukçu, Hikmet Can and Boursier, Guilaine and Panteghini, Mauro and Bernabeu-Andreu, Francisco and Milinković, Neda and Mesko Brguljan, Pika and Linko, Solveig and Brugnoni, Duilio and O'Kelly, Ruth and Kroupis, Christos and Lohmander, Maria and Šprongl, Luděk and Vanstapel, Florent and Thelen, Marc", year = "2022", abstract = "Clinicians trust medical laboratories to provide reliable results on which they rely for clinical decisions. Lab- oratories fulfil their responsibility for accurate and consistent results by utilizing an arsenal of approaches, ranging from validation and verification experiments to daily quality control procedures. All these procedures verify, on different moments, that the results of a certain examination procedure have analytical performance characteristics (APC) that meet analytical performance specifications (APS) set for a particular intended use. The APC can in part be determined by esti- mating the measurement uncertainty component under con- ditions of within-laboratory precision (uRw), which comprises all components influencing the measurement uncertainty of random sources. To maintain the adequacy of their mea- surement procedures, laboratories need to distinguish aspects that are manageable vs. those that are not. One of the aspects that may influence uRw is the momentary significant bias caused by shifts in reagent and/or calibrator lots, which, when accepted or unnoticed, become a factor of the APC. In this paper, we postulate a model for allocating a part of allowable uRw to between-reagent lot variation, based on the need for long-term consistency of the measurement variability for that specific measurand. The allocation manages the ratio between short-term and long-term variation and indicates laboratories when to reject or correct certain variations due to reagent lots.", publisher = "De Gruyter Open Ltd", journal = "Clinical Chemistry and Laboratory Medicine", title = "An approach for determining allowable between reagent lot variation", volume = "60", number = "5", pages = "681-688", doi = "10.1515/cclm-2022-0083" }
Van Schrojenstein Lantman, M., Çubukçu, H. C., Boursier, G., Panteghini, M., Bernabeu-Andreu, F., Milinković, N., Mesko Brguljan, P., Linko, S., Brugnoni, D., O'Kelly, R., Kroupis, C., Lohmander, M., Šprongl, L., Vanstapel, F.,& Thelen, M.. (2022). An approach for determining allowable between reagent lot variation. in Clinical Chemistry and Laboratory Medicine De Gruyter Open Ltd., 60(5), 681-688. https://doi.org/10.1515/cclm-2022-0083
Van Schrojenstein Lantman M, Çubukçu HC, Boursier G, Panteghini M, Bernabeu-Andreu F, Milinković N, Mesko Brguljan P, Linko S, Brugnoni D, O'Kelly R, Kroupis C, Lohmander M, Šprongl L, Vanstapel F, Thelen M. An approach for determining allowable between reagent lot variation. in Clinical Chemistry and Laboratory Medicine. 2022;60(5):681-688. doi:10.1515/cclm-2022-0083 .
Van Schrojenstein Lantman, Marith, Çubukçu, Hikmet Can, Boursier, Guilaine, Panteghini, Mauro, Bernabeu-Andreu, Francisco, Milinković, Neda, Mesko Brguljan, Pika, Linko, Solveig, Brugnoni, Duilio, O'Kelly, Ruth, Kroupis, Christos, Lohmander, Maria, Šprongl, Luděk, Vanstapel, Florent, Thelen, Marc, "An approach for determining allowable between reagent lot variation" in Clinical Chemistry and Laboratory Medicine, 60, no. 5 (2022):681-688, https://doi.org/10.1515/cclm-2022-0083 . .