FarFaR - Pharmacy Repository
University of Belgrade, Faculty of Pharmacy
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrillic)
    • Serbian (Latin)
  • Login
View Item 
  •   FarFaR
  • Pharmacy
  • Radovi istraživača / Researchers’ publications
  • View Item
  •   FarFaR
  • Pharmacy
  • Radovi istraživača / Researchers’ publications
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Chiral ligand-exchange chromatography for diastereo-enantio separation of exametazime

Authorized Users Only
2003
Authors
Nikolić, N
Veselinović, D
Vucina, J
Lingeman, H
Karljiković-Rajić, Katarina
Article (Published version)
Metadata
Show full item record
Abstract
The diastereo-enantio separation of isomeric mixtures of exametazime (HM-PAO) by liquid chromatography is described using an achiral sorbent (RP-18). A chiral eluent with the initial complex of Cu(II) and the optically active selector N,N-dimethyl-l-phenylalanine (l-DM-PhA), based on the ligand-exchange principle, has been applied. The separation is based on the presence of the immobilized binary complex Cu(l-DM-PhA)(2) and formation of mixed ternary complex. The optimal mole ratio of Cu(II):l-DM-PhA is 1:4, the pH should be between 4.1 and 4.2 and up to 0.8 mM of triethylamine is added for column presaturation with the initial complex. The elution order has been defined using isolated l-HM-PAO via l-HM-PAO L(+)tartrate and tneso-HM-PAO obtained by repeated recrystallization from the isomeric mixture of HM-PAO. Complete resolution between all isomers (R-S from 2.14 to 3.91) and partial resolution for meso(EE)/l-HM-PAO (R-S = 0.83) has been obtained. This means that the proposed chiral ...ligand-exchange chromatography (CLEC) can be used for determination of the isomeric purity of HM-PAO. This as an alternative method for resolution measurements with chiral columns.

Keywords:
column liquid chromatography / ligand-exchange chromatography / chiral separation / exametazime (HM-PAO)
Source:
Journal of Pharmaceutical and Biomedical Analysis, 2003, 32, 6, 1159-1166
Publisher:
  • Pergamon-Elsevier Science Ltd, Oxford

DOI: 10.1016/S0731-7085(03)00230-9

ISSN: 0731-7085

PubMed: 12907259

WoS: 000185148800007

Scopus: 2-s2.0-0043205804
[ Google Scholar ]
7
9
URI
https://farfar.pharmacy.bg.ac.rs/handle/123456789/436
Collections
  • Radovi istraživača / Researchers’ publications
Institution/Community
Pharmacy
TY  - JOUR
AU  - Nikolić, N
AU  - Veselinović, D
AU  - Vucina, J
AU  - Lingeman, H
AU  - Karljiković-Rajić, Katarina
PY  - 2003
UR  - https://farfar.pharmacy.bg.ac.rs/handle/123456789/436
AB  - The diastereo-enantio separation of isomeric mixtures of exametazime (HM-PAO) by liquid chromatography is described using an achiral sorbent (RP-18). A chiral eluent with the initial complex of Cu(II) and the optically active selector N,N-dimethyl-l-phenylalanine (l-DM-PhA), based on the ligand-exchange principle, has been applied. The separation is based on the presence of the immobilized binary complex Cu(l-DM-PhA)(2) and formation of mixed ternary complex. The optimal mole ratio of Cu(II):l-DM-PhA is 1:4, the pH should be between 4.1 and 4.2 and up to 0.8 mM of triethylamine is added for column presaturation with the initial complex. The elution order has been defined using isolated l-HM-PAO via l-HM-PAO L(+)tartrate and tneso-HM-PAO obtained by repeated recrystallization from the isomeric mixture of HM-PAO. Complete resolution between all isomers (R-S from 2.14 to 3.91) and partial resolution for meso(EE)/l-HM-PAO (R-S = 0.83) has been obtained. This means that the proposed chiral ligand-exchange chromatography (CLEC) can be used for determination of the isomeric purity of HM-PAO. This as an alternative method for resolution measurements with chiral columns.
PB  - Pergamon-Elsevier Science Ltd, Oxford
T2  - Journal of Pharmaceutical and Biomedical Analysis
T1  - Chiral ligand-exchange chromatography for diastereo-enantio separation of exametazime
VL  - 32
IS  - 6
SP  - 1159
EP  - 1166
DO  - 10.1016/S0731-7085(03)00230-9
ER  - 
@article{
author = "Nikolić, N and Veselinović, D and Vucina, J and Lingeman, H and Karljiković-Rajić, Katarina",
year = "2003",
abstract = "The diastereo-enantio separation of isomeric mixtures of exametazime (HM-PAO) by liquid chromatography is described using an achiral sorbent (RP-18). A chiral eluent with the initial complex of Cu(II) and the optically active selector N,N-dimethyl-l-phenylalanine (l-DM-PhA), based on the ligand-exchange principle, has been applied. The separation is based on the presence of the immobilized binary complex Cu(l-DM-PhA)(2) and formation of mixed ternary complex. The optimal mole ratio of Cu(II):l-DM-PhA is 1:4, the pH should be between 4.1 and 4.2 and up to 0.8 mM of triethylamine is added for column presaturation with the initial complex. The elution order has been defined using isolated l-HM-PAO via l-HM-PAO L(+)tartrate and tneso-HM-PAO obtained by repeated recrystallization from the isomeric mixture of HM-PAO. Complete resolution between all isomers (R-S from 2.14 to 3.91) and partial resolution for meso(EE)/l-HM-PAO (R-S = 0.83) has been obtained. This means that the proposed chiral ligand-exchange chromatography (CLEC) can be used for determination of the isomeric purity of HM-PAO. This as an alternative method for resolution measurements with chiral columns.",
publisher = "Pergamon-Elsevier Science Ltd, Oxford",
journal = "Journal of Pharmaceutical and Biomedical Analysis",
title = "Chiral ligand-exchange chromatography for diastereo-enantio separation of exametazime",
volume = "32",
number = "6",
pages = "1159-1166",
doi = "10.1016/S0731-7085(03)00230-9"
}
Nikolić, N., Veselinović, D., Vucina, J., Lingeman, H.,& Karljiković-Rajić, K.. (2003). Chiral ligand-exchange chromatography for diastereo-enantio separation of exametazime. in Journal of Pharmaceutical and Biomedical Analysis
Pergamon-Elsevier Science Ltd, Oxford., 32(6), 1159-1166.
https://doi.org/10.1016/S0731-7085(03)00230-9
Nikolić N, Veselinović D, Vucina J, Lingeman H, Karljiković-Rajić K. Chiral ligand-exchange chromatography for diastereo-enantio separation of exametazime. in Journal of Pharmaceutical and Biomedical Analysis. 2003;32(6):1159-1166.
doi:10.1016/S0731-7085(03)00230-9 .
Nikolić, N, Veselinović, D, Vucina, J, Lingeman, H, Karljiković-Rajić, Katarina, "Chiral ligand-exchange chromatography for diastereo-enantio separation of exametazime" in Journal of Pharmaceutical and Biomedical Analysis, 32, no. 6 (2003):1159-1166,
https://doi.org/10.1016/S0731-7085(03)00230-9 . .

DSpace software copyright © 2002-2015  DuraSpace
About FarFaR - Pharmacy Repository | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About FarFaR - Pharmacy Repository | Send Feedback

OpenAIRERCUB