Application of moving average procedures as an additional tool for continuous quality control of analytical work in the medical laboratory

dc.contributor.advisorIgnjatović, Svetlana
dc.contributor.otherTopić, Aleksandra
dc.contributor.otherDopsaj, Violeta
dc.contributor.otherŠipetić-Grujičić, Sandra
dc.creatorLukić, Vera
dc.date.accessioned2023-08-24T07:46:41Z
dc.date.available2023-08-24T07:46:41Z
dc.date.issued2022
dc.identifier.urihttps://eteze.bg.ac.rs/application/showtheses?thesesId=9093
dc.identifier.urihttps://fedorabg.bg.ac.rs/fedora/get/o:29371/bdef:Content/download
dc.identifier.urihttps://plus.cobiss.net/cobiss/sr/sr/bib/72889097
dc.identifier.urihttps://nardus.mpn.gov.rs/handle/123456789/21432
dc.identifier.urihttps://farfar.pharmacy.bg.ac.rs/handle/123456789/4967
dc.description.abstractTradicionalno se unutrašnja kontrola kvaliteta (QC) analitičkog rada umedicinskim laboratorijama sprovodi testiranjem komercijalno dostupnih kontrolnihmaterijala u određenim vremenskim intervalima. Međutim, ova kontrola ima svojenedostatke, a to su: intermitentnost, problem komutabilnosti, kao i cena materijala irada. S obzirom na to, u savremenoj laboratorijskoj praksi razmatra se izrada QC planazasnovanog na riziku i uvođenje kontrolnih procedura zasnovanih na rezultatimapacijenata (eng. patient-based real-time quality control, PBRTQC). PBRTQC je, za razlikuod tradicionalne, kontinuirana, oslobođena problema komutabilnosti i bez troškovakontrolnog materijala. Jedan od mogućih načina korišćenja rezultata pacijenata u svrhukontrole kvaliteta analitičkog rada jeste moving average (MA). MA podrazumevaizračunavanje prosečne vrednosti iz dobijenog seta rezultata pacijenata i dalje korišćenjete vrednosti u kontrolne svrhe. Učestalost QC merenja u QC planu zasnovanom nariziku zavisi od sigma metrike testa, kao mere kvaliteta. Za testove čija sigma metrikaima niske vrednosti potrebne su kontrolne strategije koje su kompleksne i skupe. Kodovakvih testova može se razmotriti uvođenje PBRTQC procedura u rutinski plankontrole kvaliteta. I pitanje izrade QC plana zasnovanog na riziku, kao i pitanjeimplementacije MA kontrolnih procedura, nedovoljno su istraženi u slučaju laboratorijasa malim dnevnim obimom testiranja.Ciljevi: Ciljevi ovog naučnog istraživanja bili su da se u medicinskoj laboratorijisa malim dnevnim obimom testiranja odaberu i optimizuju MA procedure za desetbiohemijskih analita, da se optimizovane MA procedure kroz LIS implementiraju u rutinski rad laboratorije, da se uspostavi protokol za postupanje sa MA alarmima i da seMA procedure integrišu u laboratorijski QC plan zasnovan na riziku.sr
dc.description.abstractTraditionally, the internal quality control (QC) of analytical work inmedical laboratories is carried out by testing commercially available control materials atcertain time intervals. However, this type of control has drawbacks, includingintermittency, the problem of commutability, and the cost of materials and labor.Therefore, modern laboratory practice considers the development of risk-based QCplans and the introduction of patient-based real-time quality control (PBRTQC)procedures. Unlike traditional QC, PBRTQC is continuous, free of the problem ofcommutability and the cost of control material. One of the possible ways to use patientresults for the quality control of analytical work is the moving average (MA). MAinvolves calculating the average value from the obtained set of patient results andfurther using that value for control purposes. The frequency of QC measurements in arisk-based QC plan depends on the sigma metrics of the test as a measure of quality.Tests with low values of sigma metrics require control strategies that are complex andexpensive. The laboratory may consider introducing PBRTQC procedures into a routineQC plan in such tests. In the case of laboratories with a small daily testing volume, theissue of developing a risk-based QC plan and implementing MA control proceduresremains insufficiently investigated.Objectives: The objectives of this scientific research were to select and optimize MAprocedures for 10 biochemical analytes in a medical laboratory with a small dailyvolume of testing, to implement optimized MA procedures through the laboratoryinformation system (LIS) in routine laboratory work, to establish a protocol for handlingMA alarms, and to integrate MA procedures into a laboratory risk-based QC plan.en
dc.formatapplication/pdf
dc.languagesr
dc.publisherУниверзитет у Београду, Фармацеутски факултетsr
dc.rightsopenAccessen
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceУниверзитет у Београдуsr
dc.subjectkontrola kvalitetasr
dc.subjectkontrola kvaliteta u realnom vremenu baziran na rezultatima pacijenata
dc.subjectmoving average
dc.subjectplan kontrole kvaliteta zasnovan na riziku
dc.subjectquality control
dc.subjectpatient-based real-time quality control
dc.subjectrisk-based quality control plan
dc.titlePrimena moving average procedura kao dodatnog alata za kontinuiranu kontrolu kvaliteta analitičkog rada u medicinskoj laboratorijisr
dc.title.alternativeApplication of moving average procedures as an additional tool for continuous quality control of analytical work in the medical laboratoryen
dc.typedoctoralThesisen
dc.rights.licenseBY-NC-ND
dc.identifier.fulltexthttp://farfar.pharmacy.bg.ac.rs/bitstream/id/13655/Disertacija_13533.pdf
dc.identifier.fulltexthttp://farfar.pharmacy.bg.ac.rs/bitstream/id/14605/Referat.pdf
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_nardus_21432
dc.type.versionpublishedVersion


Документи

Thumbnail
Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу