Baošić, Rada

Link to this page

Authority KeyName Variants
orcid::0000-0003-2778-9980
  • Baošić, Rada (1)
  • Baošić, Rada M. (1)
Projects

Author's Bibliography

A Simple Flow Injection System for Amperometric Detection of Ascorbic Acid Using Carbon Paste/Copper Schiff Base Composite Electrode

Kulizić, Mihajlo; Stanković, Milan; Rašić, Marija; Mijatović, Aleksandar; Baošić, Rada; Lolić, Aleksandar

(John Wiley and Sons Inc, 2023)

TY  - JOUR
AU  - Kulizić, Mihajlo
AU  - Stanković, Milan
AU  - Rašić, Marija
AU  - Mijatović, Aleksandar
AU  - Baošić, Rada
AU  - Lolić, Aleksandar
PY  - 2023
UR  - https://farfar.pharmacy.bg.ac.rs/handle/123456789/5406
AB  - In this paper, a simple, sensitive, and precise flow injection system was optimized and applied to ascorbic acid determination with a carbon paste electrode modified with the Schiff base copper complex. The modified sensor showed increased sensitivity toward ascorbic acid oxidation with a decrease of oxidation potential by 200 mV. Under optimized flow parameters, working potential, gasket thickness, sample and reaction coil volumes, and flow rate, the developed flow system gave a linear response from 5 to 75 μmol/L of ascorbic acid. The calculated limit of detection was 4.5 μmol/L, calculated as 3σ/s which corresponds to the absolute value of 40 ng for the 50 μL sample coil. The precision for six consecutive injections of 5 and 75 μmol/L ascorbic acid solutions was determined as a relative standard deviation of 5.8 % and 1.5 %, respectively. The flow injection system enabled up to 120 analyses per hour. An optimized flow system was applied to the determination of ascorbic acid in dietary supplements, after simple preparation.
PB  - John Wiley and Sons Inc
T2  - ChemistrySelect
T1  - A Simple Flow Injection System for Amperometric Detection of Ascorbic Acid Using Carbon Paste/Copper Schiff Base Composite Electrode
VL  - 8
IS  - 48
DO  - 10.1002/slct.202304631
ER  - 
@article{
author = "Kulizić, Mihajlo and Stanković, Milan and Rašić, Marija and Mijatović, Aleksandar and Baošić, Rada and Lolić, Aleksandar",
year = "2023",
abstract = "In this paper, a simple, sensitive, and precise flow injection system was optimized and applied to ascorbic acid determination with a carbon paste electrode modified with the Schiff base copper complex. The modified sensor showed increased sensitivity toward ascorbic acid oxidation with a decrease of oxidation potential by 200 mV. Under optimized flow parameters, working potential, gasket thickness, sample and reaction coil volumes, and flow rate, the developed flow system gave a linear response from 5 to 75 μmol/L of ascorbic acid. The calculated limit of detection was 4.5 μmol/L, calculated as 3σ/s which corresponds to the absolute value of 40 ng for the 50 μL sample coil. The precision for six consecutive injections of 5 and 75 μmol/L ascorbic acid solutions was determined as a relative standard deviation of 5.8 % and 1.5 %, respectively. The flow injection system enabled up to 120 analyses per hour. An optimized flow system was applied to the determination of ascorbic acid in dietary supplements, after simple preparation.",
publisher = "John Wiley and Sons Inc",
journal = "ChemistrySelect",
title = "A Simple Flow Injection System for Amperometric Detection of Ascorbic Acid Using Carbon Paste/Copper Schiff Base Composite Electrode",
volume = "8",
number = "48",
doi = "10.1002/slct.202304631"
}
Kulizić, M., Stanković, M., Rašić, M., Mijatović, A., Baošić, R.,& Lolić, A.. (2023). A Simple Flow Injection System for Amperometric Detection of Ascorbic Acid Using Carbon Paste/Copper Schiff Base Composite Electrode. in ChemistrySelect
John Wiley and Sons Inc., 8(48).
https://doi.org/10.1002/slct.202304631
Kulizić M, Stanković M, Rašić M, Mijatović A, Baošić R, Lolić A. A Simple Flow Injection System for Amperometric Detection of Ascorbic Acid Using Carbon Paste/Copper Schiff Base Composite Electrode. in ChemistrySelect. 2023;8(48).
doi:10.1002/slct.202304631 .
Kulizić, Mihajlo, Stanković, Milan, Rašić, Marija, Mijatović, Aleksandar, Baošić, Rada, Lolić, Aleksandar, "A Simple Flow Injection System for Amperometric Detection of Ascorbic Acid Using Carbon Paste/Copper Schiff Base Composite Electrode" in ChemistrySelect, 8, no. 48 (2023),
https://doi.org/10.1002/slct.202304631 . .
1

Thin-layer chromatography of several antihypertensive drugs from the group of angiotensin converting enzyme inhibitors

Aleksić, Mirjana; Agbaba, Danica; Baošić, Rada M.; Milojković-Opsenica, Dušanka; Tešić, Živoslav

(Srpsko hemijsko društvo, Beograd, 2001)

TY  - JOUR
AU  - Aleksić, Mirjana
AU  - Agbaba, Danica
AU  - Baošić, Rada M.
AU  - Milojković-Opsenica, Dušanka
AU  - Tešić, Živoslav
PY  - 2001
UR  - https://farfar.pharmacy.bg.ac.rs/handle/123456789/308
AB  - A rapid and simple method for the chromatographic separation of pharmacologically active components contained in some antihypertensive drugs has been developed employing thin-layers of silica gel and polyacrylonitrile sorbent (PANS). The active compounds of Captopril - (S)-1-(3-mercapto-2- methyl-1-oxopropyl)-L-proline, Enalapril - (S)-1-[N-[1-(ethoxycarbonyl)-3- phenylpropyl]-L-alanyl]-L-proline, Lisinopril - (S) -1-[N2-(carboxy-3- phenylpropyl)-L-lysyl]-L-proline, Quinapril - [3S-[2[R*(R*)],3R*]],-2-[2-[[1 (-ethoxycarbonyl)-3-phenylpropyl]amino]-1-oxopropyl]-1,2,3,4-tetrahydro-3- iso-quinoline-carboxylic acid, Ramipril - [2S-[1[R*(R*)],2α,3αβ,6αβ]]-1-[2[[ 1-(ethoxycarbonyl)-3-phenylpropyl]amino]-1-oxopropyl]octahydrocyclopenta[β]- pyrole-2-carboxylic acid and Cilazapril - [1S-[1α,9α(R*)]]-9-[[1- (ethoxycarbonyl)-3-phenylpropyl]amino]octahydro-10-oxo-6H-pyridazino[1,2-α] [1,2]diazepine-1-carboxylic acid, were successfully separated by the presented procedures. For their chromatographic separation on silica gel sixteen and on PANS thirteen solvents were used.
AB  - U radu je u uslovima hromatografije na tankim slojevima silika-gela i poliakrilonitrilnog sorbenta (PANS-a), izvršeno razdvajanje sledećih antihipertenziva iz grupe angiotenzin konvertujućih enzim inhibitora (ACE inhibitora): Kaptopril-a, Enalapril-a, Lizinopril-a, Kvinapril-a, Ramipril-a, Cilazapril-a. Za njihovo hromatografsko razdvajanje upotrebljeni su mnogi rastvarači. Na osnovu dobijenih rezultata diskutovani su mehanizmi odvajanja. Na taj način data je jedna veoma brza i jednostavna metoda za odvajanje pomenutih supstanci.
PB  - Srpsko hemijsko društvo, Beograd
T2  - Journal of the Serbian Chemical Society
T1  - Thin-layer chromatography of several antihypertensive drugs from the group of angiotensin converting enzyme inhibitors
T1  - Tankoslojna hromatografija nekih antihipertenziva iz grupe angiotenzin konvertujućih enzim inhibitora
VL  - 66
IS  - 1
SP  - 39
EP  - 44
UR  - https://hdl.handle.net/21.15107/rcub_farfar_308
ER  - 
@article{
author = "Aleksić, Mirjana and Agbaba, Danica and Baošić, Rada M. and Milojković-Opsenica, Dušanka and Tešić, Živoslav",
year = "2001",
abstract = "A rapid and simple method for the chromatographic separation of pharmacologically active components contained in some antihypertensive drugs has been developed employing thin-layers of silica gel and polyacrylonitrile sorbent (PANS). The active compounds of Captopril - (S)-1-(3-mercapto-2- methyl-1-oxopropyl)-L-proline, Enalapril - (S)-1-[N-[1-(ethoxycarbonyl)-3- phenylpropyl]-L-alanyl]-L-proline, Lisinopril - (S) -1-[N2-(carboxy-3- phenylpropyl)-L-lysyl]-L-proline, Quinapril - [3S-[2[R*(R*)],3R*]],-2-[2-[[1 (-ethoxycarbonyl)-3-phenylpropyl]amino]-1-oxopropyl]-1,2,3,4-tetrahydro-3- iso-quinoline-carboxylic acid, Ramipril - [2S-[1[R*(R*)],2α,3αβ,6αβ]]-1-[2[[ 1-(ethoxycarbonyl)-3-phenylpropyl]amino]-1-oxopropyl]octahydrocyclopenta[β]- pyrole-2-carboxylic acid and Cilazapril - [1S-[1α,9α(R*)]]-9-[[1- (ethoxycarbonyl)-3-phenylpropyl]amino]octahydro-10-oxo-6H-pyridazino[1,2-α] [1,2]diazepine-1-carboxylic acid, were successfully separated by the presented procedures. For their chromatographic separation on silica gel sixteen and on PANS thirteen solvents were used., U radu je u uslovima hromatografije na tankim slojevima silika-gela i poliakrilonitrilnog sorbenta (PANS-a), izvršeno razdvajanje sledećih antihipertenziva iz grupe angiotenzin konvertujućih enzim inhibitora (ACE inhibitora): Kaptopril-a, Enalapril-a, Lizinopril-a, Kvinapril-a, Ramipril-a, Cilazapril-a. Za njihovo hromatografsko razdvajanje upotrebljeni su mnogi rastvarači. Na osnovu dobijenih rezultata diskutovani su mehanizmi odvajanja. Na taj način data je jedna veoma brza i jednostavna metoda za odvajanje pomenutih supstanci.",
publisher = "Srpsko hemijsko društvo, Beograd",
journal = "Journal of the Serbian Chemical Society",
title = "Thin-layer chromatography of several antihypertensive drugs from the group of angiotensin converting enzyme inhibitors, Tankoslojna hromatografija nekih antihipertenziva iz grupe angiotenzin konvertujućih enzim inhibitora",
volume = "66",
number = "1",
pages = "39-44",
url = "https://hdl.handle.net/21.15107/rcub_farfar_308"
}
Aleksić, M., Agbaba, D., Baošić, R. M., Milojković-Opsenica, D.,& Tešić, Ž.. (2001). Thin-layer chromatography of several antihypertensive drugs from the group of angiotensin converting enzyme inhibitors. in Journal of the Serbian Chemical Society
Srpsko hemijsko društvo, Beograd., 66(1), 39-44.
https://hdl.handle.net/21.15107/rcub_farfar_308
Aleksić M, Agbaba D, Baošić RM, Milojković-Opsenica D, Tešić Ž. Thin-layer chromatography of several antihypertensive drugs from the group of angiotensin converting enzyme inhibitors. in Journal of the Serbian Chemical Society. 2001;66(1):39-44.
https://hdl.handle.net/21.15107/rcub_farfar_308 .
Aleksić, Mirjana, Agbaba, Danica, Baošić, Rada M., Milojković-Opsenica, Dušanka, Tešić, Živoslav, "Thin-layer chromatography of several antihypertensive drugs from the group of angiotensin converting enzyme inhibitors" in Journal of the Serbian Chemical Society, 66, no. 1 (2001):39-44,
https://hdl.handle.net/21.15107/rcub_farfar_308 .
8
10